SLUSFF2C September 2023 – December 2025 UCG28824 , UCG28826 , UCG28828
PRODUCTION DATA
The UCG2882x offers different fault protections which can be programmed for auto-retry or latched response using an appropriate resistor on the FCL pin, as per values in Table 7-4. In auto-retry response, once a protection is triggered, switching stops for 1s duration and normal operation resumes thereafter, as shown in Figure 7-12. When latched response is used, on triggering a protection, the device waits for the supply voltage, VCC to reduce below VVCC(OFF) followed by recovery to greater than VVCC(REG) to resume switching and normal operation, as shown in Figure 7-13.