SLUSFP1B April 2025 – November 2025 UCC34141-Q1
ADVANCE INFORMATION
UCC34141-Q1 integrates the primary-side, secondary-side power stages, as well as the isolation transformer. The power loss caused by the power conversion causes the module temperature higher than the ambient temperature. For the safe operation of the power module, the UCC34141-Q1 is equipped with over-temperature protection. Both the primary-side power stage, and the secondary-side power stage temperatures are sensed and compared with the over-temperature protection threshold. If the primary-side power stage temperature becomes higher than TSHUT_P_R, or the secondary-side power stage temperature becomes higher than TSHUT_S_R, the module enters over-temperature protection mode. The module stops switching and the Power-Good pin change to non-active status.