Figure 3-41 to Figure 3-44 below show output voltage VOUT deviation when load current step change is between 0 and 100%, at 100Hz rate at 2.5A/us. Note, the step load current is inverted in the capture.
Green (AC coupled)= VOUT, Pink= Load Current.
Figure 3-41 Load Transient Response at VOUT = 20V Overshoot / Undershoot = 495mV / -680mV
Figure 3-42 Transient Response at VOUT = 15V Overshoot / Undershoot = 485mV / -630mV
Figure 3-43 Transient Response at VOUT = 9V Overshoot / Undershoot = 460mV / -500mV
Figure 3-44 Transient Response at VOUT = 5V Overshoot / Undershoot = 440mV / -480mV