SLVSGS5A December 2023 – June 2024 DRV3946-Q1
PRODUCTION DATA
At any time during active operation (with or without internal regulation), the user can issue a SPI Hi-Z command or drive the EN/IN2 and DIS/EN2 to turn OFF the drivers.
Two types of SPI commands are supported for turn OFF – CMD1 for a specific node addressed device in the SPI bus or CMD2 for all devices in the SPI bus (Broadcast command).
Following the command, the device will briefly recirlculate the current to ensure that the load current is less than the hold target (HC) or lower hold ripple target (HCR-) and then turn off (Hi-Z) the driver with QTO clamping.
The clamping will ensure a large voltage acorss the load to rapidly decay the load current.
QTO start and done is detected by comparing the voltage on the output with respect to PVDD.
Following QTO_DONE detection, there is a 1 ms wait before going to the STANDBY state.
Depending on the user configured RETRY WAIT, an additional wait period is enforced as minimum cool off period even if the driver is commanded ON by the user.