SLVSGS5A December 2023 – June 2024 DRV3946-Q1
PRODUCTION DATA
The device measures the following ramp times and issues warning for min/max time violation:
Ramp up time to peak current (flag CHx_PRT_W)
Ramp down time from peak to hold current (flag CHx_HRT_W)
QTO (Clamping) time (flag CHx_QTOT_W)
The conditions for the time violation are described in Section 7.1.3 and Section 7.1.4 sections.
The measured times are also recorded in the measurement registers. Average duty cycle measurement is also provided. Refer Measurement registers for details.