Mechanism & thresholds: If the supply voltage on the VM pin drops below the threshold, set by VVMUV for a time greater than tVMUV, then an VM under voltage fault is detected.
Action:
nFAULT pin is asserted low
Both OUTx is Hi-Z
IPROPI pin is Hi-Z
HW variant: Reaction configurable between retry and latch as per DIAG setting
SPI variant: Reaction configurable between retry and latch setting
Note that retry time is only dependent on recovery of VM under voltage condition and is independent of tRETRY / tCLEAR times