SLVSIR8 June 2026 TPS61383-Q1
PRODUCTION DATA
TPS61383-Q1 integrates Li-ion and LiFePO4 battery charging profile supporting 50 – 100mA LDO charging or 500mA – 5A buck charging. In Lithium charging mode, TPS61383-Q1 charges batteries with a voltage-controlled charging profile consisting of four phases: trickle charge, pre-charge, CC charge, and CV charge.
When the backup battery voltage is below VBUB_SHORT threshold, the device enters trickle charge phase. In this phase, the device charges the battery by 15mA LDO mode to protect the safety of lithium battery.
When the battery voltage is charged to VBUB_SHORT threshold but still below VBUB_LOWV threshold, the device enters pre-charge phase. In this phase, the device charges the battery with 20% of the CC current set in I2C BUB_CC bits (Register 05H: CHGR_SET2). Lithium battery within this voltage range is considered as normal but low battery, so charging current is limited at 20% of CC current to protect battery life.
If the battery voltage does not reach VBUB_LOWV threshold within 30 minutes. The battery is considered damaged and internal short-circuit. The IC terminates charging and I2C bit BUB_SHORT (Register 0CH: FAULT_CONDITION) is set to 1 to indicate a battery short situation.
After battery voltage reaches VBUB_LOWV threshold, the device enters CC charge phase. In this phase, the device charges the battery by CC current (Set by I2C Register 05H: CHGR_SET2, BUB_CC bits).
After the battery is charged to the target voltage (set by I2C bits BUB_CV and BUB_CELL), TPS61383-Q1 enters CV charge phase. The device decrease charging current to regulate battery voltage until the charging current drops below termination threshold ITERM (set by Register 06H: CHGR_SET3, CHG_TEM_CURRENT bit), then the device terminates charging.
If configured as recharge disabled (By I2C bits BUB_TER), the device does not re-charge after terminated unless the EN_CHGR pin or CHGR_EN bit is toggled.
If configured as recharge enabled, the device pauses charging temporary and automatically re-charges when the BUB voltage drops below the VRECHG threshold.