SLVUCU5 December 2025 UCD91160 , UCD91320
When monitoring the voltage of a particular rail, a fault or warning event occurs when the voltage exceeds the user-configurable voltage thresholds. When a fault is detected, the device responds with user-defined actions (fault response).
For faster response and more flexible configuration, UCD91xxx devices support the Rail Profile feature, which is only available for rails monitoring voltage.
Each rail can have up to for profiles, where the application can switch between profiles using two assigned GPIs. A Rail Profile consists of nine thresholds, set by the following PMBus commands:
VOUT_COMMAND
VOUT_OV_FAULT_LIMIT
VOUT_OV_WARNING_LIMIT
VOUT_MARGIN_HIGH
POWER_GOOD_ON
VOUT_MARGIN_LOW
POWER_GOOD_OFF
VOUT_UV_WARNING_LIMIT
VOUT_UV_FAULT_LIMIT
UCD91xxx offers a total of 50 individual profiles shared among all rails, where each rail can have at least one, but not more than four profiles. Switching between rails is controlled by two GPIs, and a programmable block-out period is used to block all voltage-related faults on the given rail when switching profiles.
The following PMBus commands are used for Rail Profile configuration:
For configuration the GPIs used for switching and the switching block-out period