The performance of switching converters
heavily depends on the quality of the PCB layout. Poor PCB design can cause among others
converter instability, load regulation problems, noise or EMI issues. Do not use thermal
relieved connections in the power path for VCC because the thermal relieved connections add
significant inductance.
- Place the VCC and BIAS capacitors close
to the corresponding device pins. Connect the capacitors with short and wide traces to
minimize inductance as the capacitors carry high peak currents. Connect the VCC capacitors
ground to power ground (PGND) and the BIAS capacitors ground to analog ground (AGND).
- Place CSA and CSB filter resistors and
capacitors close to the corresponding device pins to minimize noise coupling between the
filter and the device. Route the traces to the sense resistor RCS, which is
placed close to the inductor, as differential pair and surrounded by ground to avoid noise
coupling. Use Kelvin connections to the sense resistor.
- Place the compensation network
RCOMP and CCOMP as well as the frequency setting resistor
RRT close to the corresponding device pins and connect them with short traces
to avoid noise coupling. Connect the analog ground pin AGND to these components.
- Place the ATRK resistor RATRK
(when used) close to the ATRK pin and connect RATRK to AGND.
- The layout of following components is not
as critical:
- Soft-Start capacitor
CSS
- DLY capacitor CDLY
- ILIM/IMON resistor and capacitor
RILIM and CILIM
- CFG1, CFG2 and SYNCOUT
resistors
- UVLO/EN resistors
- Place the filter VOUT
capacitors (small size ceramic) close to the VOUT-pin. Use short and wide traces to
minimize the power stage loop COUT to VOUT connection to avoid high voltage
spikes.
- Connect the PGND-pin connection with
short and wide traces to the VOUT and VI capacitors ground to
minimize inductance causing high voltage spikes.
- TI recommends connecting the AGND and
PGND pin directly to the exposed pad (EP) to form a star connection at the device.
- Connect the device exposed pad (EP) with
several vias to a ground plane to conduct heat away.
- Separate power and signal traces and use
a ground plane to provide noise shielding.
To spread the heat generated by the
converter and the inductor, place the inductor away from the converter. However the longer
the trace between the inductor and the converter the higher the EMI and noise emissions. For
highest efficiency, connect the inductor by wide and short traces to minimize resistive
losses.