The device has the following
protections implemented. Figure 6-18 shows in which state of
the Functional State
Diagram which protection is active. The protection is active for the grey
shaded states having the same grey shading, for example TSD is active in STANDBY
state including THERMAL SHUTDOWN state but not in FAULT state.
- Thermal shutdown (TSD) turning off the device at high temperature.
- Undervoltage Lockout (UVLO) turning off the device at low supply voltage.
- VCC Undervoltage Lockout (VCC UVLO) avoiding too low low-side gate driver
voltage. The device stops switching until VCC is recovered.
- BOOT CAP Undervoltage Lockout
(BOOT CAP UVLO) avoiding too low high-side gate driver voltage. The device
initiates refresh pulses (512 cycles hiccup mode off time). See GAN Drivers, Integrated Boot Capacitor and Diode, and
Hiccup Mode Fault Protection for details.
- Overvoltage Protection (OVP),
when triggered the device stops switching until VOUT is back on
target. There are two OVPs implemented:
- OVPmax, which
is a programmable absolute value (typically 64V, 49V, 34V, or 24V). When
triggered the device either stops switching and enters FAULT state (latchICL&OVP_max = 1) or stops switching until VOUT is back on target
(latchICL&OVP_max = 0).
- OVP, which triggers when
VOUT is 110% of the programmed value. When triggered the
device stops switching until VOUT is back on target.
- Undervoltage Protection (UVP),
when triggered the device continues operation but pulls the PGOOD-pin
low.
- Peak Current Limit (PCL),
limiting the switch current. See Current Sense Setting and Switch Peak Current Limit (CSA, CSB) for details.
- Input Current Limit (ICL),
limiting the peak switch current to 120% of the peak current limit. This
protection is enabled and disabled by latchICL&OVP_max
programming.
- Average Input Current Limit
(ILIM), limiting the average input current to the programmed value by
RILIM. See Input Current Limit and Monitoring (ILIM, IMON, DLY) for details.