SNVSCM0A June 2025 – October 2025 LM51772-Q1
PRODUCTION DATA
In boost mode operation, the converter starts a boost magnetization cycle (switching state I) with the internal clock signal. After the converter samples the inductor current, the device transitions to switching state II, which is the boost demagnetization state. The maximum duty cycle in boost mode is limited by the minimum boost on-time and the selected switching frequency.