PG_STATUS1 is shown in Figure 6-60 and described in Table 6-54.
Return to Summary Table.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| LDOA2_PGOOD | SWA1_PGOOD | BUCK6_PGOOD | BUCK5_PGOOD | BUCK4_PGOOD | BUCK3_PGOOD | BUCK2_PGOOD | BUCK1_PGOOD |
| R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | LDOA2_PGOOD | R | 0h | LDOA2 power good status. 0h = The output is not in target regulation range. 1h = The output is in target regulation range. |
| 6 | SWA1_PGOOD | R | 0h | SWA1 power good status. 0h = The output is not in target regulation range. 1h = The output is in target regulation range. |
| 5 | BUCK6_PGOOD | R | 0h | BUCK6 power good status. 0h = The output is not in target regulation range. 1h = The output is in target regulation range. |
| 4 | BUCK5_PGOOD | R | 0h | BUCK5 power good status. 0h = The output is not in target regulation range. 1h = The output is in target regulation range. |
| 3 | BUCK4_PGOOD | R | 0h | BUCK4 power good status. 0h = The output is not in target regulation range. 1h = The output is in target regulation range. |
| 2 | BUCK3_PGOOD | R | 0h | BUCK3 power good status. 0h = The output is not in target regulation range. 1h = The output is in target regulation range. |
| 1 | BUCK2_PGOOD | R | 0h | BUCK2 power good status. 0h = The output is not in target regulation range. 1h = The output is in target regulation range. |
| 0 | BUCK1_PGOOD | R | 0h | BUCK1 power good status. 0h = The output is not in target regulation range. 1h = The output is in target regulation range. |