TIDUFE9 August 2025
Table 4-2 shows the results of
the accuracy test at different load conditions with accuracy at
power factor (PF) = 1.
| CONDITION | NUMBER OF PULSES | CURRENT | cos ϕ = 1i (0 DEGREES) | ANSI C12.1 (PF 1) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ERROR 1 | ERROR 2 | ERROR 3 | ERROR 4 | ERROR 5 | AVG ERROR % | DELTA REF | LIMIT (%) [CLASS 0.5] | LIMIT (%) [CLASS 0.2] | LIMIT (%) [CLASS 0.1] | |||
| 1 | 3 | 1 | 0.023 | 0.190 | 0.008 | –0.184 | –0.189 | –0.030 | –0.027 | 1.0 | 0.4 | 0.2 |
| 2 | 6 | 1.5 | –0.153 | –0.180 | –0.109 | –0.088 | 0.028 | –0.100 | –0.097 | 0.5 | 0.2 | 0.1 |
| 3 | 6 | 3 | –0.102 | –0.066 | –0.039 | 0.008 | 0.028 | –0.034 | –0.030 | 0.5 | 0.2 | 0.1 |
| 4 | 22 | 10 | 0.035 | 0.028 | 0.028 | 0.013 | 0.008 | 0.022 | 0.026 | 0.5 | 0.2 | 0.1 |
| 5 | 29 | 15 | 0.005 | 0.014 | 0.016 | 0.008 | –0.002 | 0.008 | REF | 0.2 | 0.1 | 0.05 |
| 6 | 58 | 30 | –0.004 | –0.008 | –0.003 | –0.001 | –0.003 | –0.004 | 0.000 | 0.5 | 0.2 | 0.1 |
| 7 | 115 | 50 | –0.01 | –0.018 | –0.01 | –0.016 | 0 | –0.011 | –0.007 | 0.5 | 0.2 | 0.1 |
| 8 | 230 | 75 | 0 | –0.002 | –0.006 | –0.003 | 0 | –0.002 | 0.002 | 0.5 | 0.2 | 0.1 |
| 9 | 298 | 90 | 0.000 | –0.003 | 0.001 | 0.004 | 0.008 | 0.002 | 0.006 | 0.5 | 0.2 | 0.1 |
| 10 | 384 | 100 | 0.006 | 0.013 | 0.015 | 0.013 | 0.010 | 0.011 | 0.015 | 0.5 | 0.2 | 0.1 |