INA190

AKTIV

Verbessertes Produkt, 40-V, bidirektionaler, hochpräziser Strommessverstärker mit Picoamp IB und ENA

Produktdetails

Product type Analog output Common-mode voltage (max) (V) 40 Common-mode voltage (min) (V) -0.2 Input offset (±) (max) (µV) 15 Input offset drift (±) (typ) (µV/°C) 0.01 Features Bidirectional, Low-side Capable, Ultra precise Rating Catalog Voltage gain (V/V) 25, 50, 100, 200, 500 CMRR (min) (dB) 132 Bandwidth (kHz) 27, 33, 35, 37, 45 Iq (max) (mA) 0.09 Number of channels 1 Comparators (#) 0 Gain error (%) 0.2, 0.3, 0.4 Gain error drift (±) (max) (ppm/°C) 7 Slew rate (V/µs) 0.3 Operating temperature range (°C) -40 to 125
Product type Analog output Common-mode voltage (max) (V) 40 Common-mode voltage (min) (V) -0.2 Input offset (±) (max) (µV) 15 Input offset drift (±) (typ) (µV/°C) 0.01 Features Bidirectional, Low-side Capable, Ultra precise Rating Catalog Voltage gain (V/V) 25, 50, 100, 200, 500 CMRR (min) (dB) 132 Bandwidth (kHz) 27, 33, 35, 37, 45 Iq (max) (mA) 0.09 Number of channels 1 Comparators (#) 0 Gain error (%) 0.2, 0.3, 0.4 Gain error drift (±) (max) (ppm/°C) 7 Slew rate (V/µs) 0.3 Operating temperature range (°C) -40 to 125
SOT-SC70 (DCK) 6 4.2 mm² (2 mm × 2.1 mm) UQFN (RSW) 10 2.52 mm² (1.8 mm × 1.4 mm) SOT-23-THN (DDF) 8 8.12 mm² (2.9 mm × 2.8 mm)
  • Low input bias currents: 500 pA (typ)
    (enables microamp current measurement)
  • Low power:
    • Low supply voltage, VS: 1.7 V to 5.5 V
    • Low shutdown current: 100 nA (max)
    • Low quiescent current: 50 µA at 25°C (typ)
  • Accuracy:
    • Common-mode rejection ratio: 132 dB (min)
    • Gain error: ±0.2% (A1 device)
    • Gain drift: 7 ppm/°C (max)
    • Offset voltage, VOS: ±15 µV (max)
    • Offset drift: 80 nV/°C (max)
  • Wide common-mode voltage: –0.2 V to +40 V
  • Bidirectional current sensing capability
  • Gain options:
    • INA190A1: 25 V/V
    • INA190A2: 50 V/V
    • INA190A3: 100 V/V
    • INA190A4: 200 V/V
    • INA190A5: 500 V/V
  • Low input bias currents: 500 pA (typ)
    (enables microamp current measurement)
  • Low power:
    • Low supply voltage, VS: 1.7 V to 5.5 V
    • Low shutdown current: 100 nA (max)
    • Low quiescent current: 50 µA at 25°C (typ)
  • Accuracy:
    • Common-mode rejection ratio: 132 dB (min)
    • Gain error: ±0.2% (A1 device)
    • Gain drift: 7 ppm/°C (max)
    • Offset voltage, VOS: ±15 µV (max)
    • Offset drift: 80 nV/°C (max)
  • Wide common-mode voltage: –0.2 V to +40 V
  • Bidirectional current sensing capability
  • Gain options:
    • INA190A1: 25 V/V
    • INA190A2: 50 V/V
    • INA190A3: 100 V/V
    • INA190A4: 200 V/V
    • INA190A5: 500 V/V

The INA190 is a low-power, voltage-output, current-shunt monitor (also called a current-sense amplifier). This device is commonly used for overcurrent protection, precision current measurement for system optimization, or in closed-loop feedback circuits. The INA190 can sense drops across shunts at common-mode voltages from –0.2 V to +40 V, independent of the supply voltage.

The low input bias current of the device permits the use of larger current-sense resistors, thus providing accurate current measurements in the microamp range. The low offset voltage of the zero-drift architecture extends the dynamic range of the current measurement. This feature allows for smaller sense resistors with lower power loss, while still providing accurate current measurements.

The INA190 operates from a single 1.7-V to 5.5-V power supply, and draws a maximum of 65 µA of supply current when enabled; only 0.1 µA when disabled. Five fixed gain options are available: 25 V/V, 50 V/V, 100 V/V, 200 V/V, or 500 V/V. The device is specified over the operating temperature range of –40°C to +125°C, and offered in UQFN, SC70, and SOT-23 packages.

The INA190 is a low-power, voltage-output, current-shunt monitor (also called a current-sense amplifier). This device is commonly used for overcurrent protection, precision current measurement for system optimization, or in closed-loop feedback circuits. The INA190 can sense drops across shunts at common-mode voltages from –0.2 V to +40 V, independent of the supply voltage.

The low input bias current of the device permits the use of larger current-sense resistors, thus providing accurate current measurements in the microamp range. The low offset voltage of the zero-drift architecture extends the dynamic range of the current measurement. This feature allows for smaller sense resistors with lower power loss, while still providing accurate current measurements.

The INA190 operates from a single 1.7-V to 5.5-V power supply, and draws a maximum of 65 µA of supply current when enabled; only 0.1 µA when disabled. Five fixed gain options are available: 25 V/V, 50 V/V, 100 V/V, 200 V/V, or 500 V/V. The device is specified over the operating temperature range of –40°C to +125°C, and offered in UQFN, SC70, and SOT-23 packages.

Herunterladen Video mit Transkript ansehen Video

Ähnliche Produkte, die für Sie interessant sein könnten

Selbe Funktionalität wie der verglichene Baustein bei gleicher Anschlussbelegung.
INA186 AKTIV 40-V, bidirektionaler, hochpräziser Strommessverstärker mit Picoamp IB und ENABLE The INA186 is functionally identical with reduced accuracy at a lower price.
Selbe Funktionalität wie der verglichene Baustein bei abweichender Anschlussbelegung.
INA191 AKTIV 40 V, ultrapräziser Strommessverstärker mit ENABLE und Picoamp IB in WCSP The INA191 is functionally identical in WCSP

Technische Dokumentation

Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 16
Top-Dokumentation Typ Titel Format-Optionen Neueste englische Version herunterladen Datum
* Datenblatt INA190 Bidirectional, Low-Power, Zero-Drift, Wide Dynamic Range, Precision Current-Sense Amplifier With Enable datasheet (Rev. D) PDF | HTML 09.11.2019
Anwendungshinweis Using a PCB Copper Trace as a Current Sense Shunt Resistor (Rev. A) PDF | HTML 27.04.2026
Anwendungshinweis Optimal Layout Practices for Low-Ohmic Current Sense Resistors in Parallel PDF | HTML 12.11.2025
Anwendungshinweis Risks and Prevention of ESD, EOS, and Latch Up Events for Current Sense Amplifiers PDF | HTML 18.11.2024
Circuit design Low (microamp), high-side, current-sensing circuit with current-sensing amp (Rev. A) PDF | HTML 25.09.2024
Circuit design High-side current shunt monitor circuit to 3-V single-ended ADC (Rev. A) PDF | HTML 20.09.2024
Application brief Current Sensing Applications in Communication Infrastructure Equipment (Rev. C) PDF | HTML 08.08.2023
Application brief Improving Power Amplifier Efficiency With Current Monitors (Rev. B) PDF | HTML 24.07.2023
Anwendungshinweis Under the Hood: Full-Scale & Dynamic Range Considerations of Current Sense Amps PDF | HTML 18.11.2022
Application brief Precision Current Measurements on High-Voltage Power-Supply Rails (Rev. F) PDF | HTML 17.10.2022
E-book An Engineer's Guide to Current Sensing (Rev. B) 12.04.2022
Auswahlhilfe Current Sense Amplifiers (Rev. E) 20.09.2021
Circuit design Low-Drift, Low-Side, Bidirectional Current Sensing Circuit (Rev. A) PDF | HTML 02.12.2020
Technischer Artikel The need for current sensing in optical modules for 100G and beyond PDF | HTML 15.03.2019
Application brief Precision, Low-Side Current Measurement (Rev. B) 06.03.2019
Application brief External current sense amps vs integrated onboard amplifiers for current sensing (Rev. B) 19.02.2019

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

INA190EVM — INA190 Strommess-Evaluierungsmodul mit Layout für niedrige Spannung

Es handelt sich um ein kleines Modul mit sechs völlig unabhängigen Platinen, die vom Benutzer herausgebrochen werden können. Fünf identische Platinen (20 A Nennstrom) können für die fünf Verstärkungsvarianten verwendet werden. Für besonders stromsparende Messsysteme kann eine sechste Platine (10 A (...)
Benutzerhandbuch: PDF
Unterstützte Produkte und Hardware
Vorrätig
Limit:
??asset.out-of-stock-ti_de_DE??
Nicht verfügbar
Simulationsmodell

INA190 TINA-TI Reference Design (Rev. B)

SBOMAI7B.TSC (196 KB) - TINA-TI-Referenzdesign
Unterstützte Produkte und Hardware
Simulationsmodell

INA190 TINA-TI Spice Model (Rev. C)

SBOMAI6C.ZIP (60 KB) - TINA-TI Spice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA190A1 PSpice Model

SBOMB97.ZIP (29 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA190A2 PSpice Model

SBOMB94.ZIP (29 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA190A3 PSpice Model

SBOMB95.ZIP (29 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA190A4 PSpice Model

SBOMBB0.ZIP (29 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

INA190A5 PSpice Model

SBOMB96.ZIP (30 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationstool

TINA-TI — SPICE-basiertes analoges Simulationsprogramm

TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)

Unterstützte Produkte und Hardware
Berechnungstool

ANALOG-ENGINEER-CALC — PC software analog engineer's calculator

Der Rechner für Analogtechniker beschleunigt viele der sich wiederholenden Berechnungen, die Entwickler von analogen Schaltungsdesigns regelmäßig durchführen müssen. Dieses PC-basierte Tool bietet eine grafische Schnittstelle mit einer Liste verschiedener gebräuchlicher Berechnungen. Das Spektrum (...)

Unterstützte Produkte und Hardware
Berechnungstool

CS-AMPLIFIER-ERROR-TOOL — Current Sense Amplifier Comparison and Error Tool

Dieser Excel-Rechner bietet einen Vergleich zwischen zwei und fünf unserer Standard-Strommessverstärker und stellt eine Tabelle mit den grundlegenden Parametern der einzelnen Bausteine bereit. Dieser Rechner nimmt außerdem die vom Benutzer gemachten Systemzustandseingaben wie Gleichtaktspannung, (...)
Unterstützte Produkte und Hardware
Designtool

CIRCUIT060039 — Niedrig-(Mikroampere)-High-Side-Strommessunsschaltkreis mit Strommessverstärker

Dieser Schaltkreis veranschaulicht, wie ein Strommessverstärker zur präzisen und zuverlässigen Messung kleiner Mikroverstärkerströme und zur Maximierung des Dynamikbereichs verwendet werden kann. Die folgende Fehleranalyse kann auf viele Strommessverstärker angewendet werden. Dieses Design basiert (...)
Unterstützte Produkte und Hardware
Referenzdesign

TIDA-00302 — Strom-Shunt-Monitor mit transienter Robustheit – Referenzdesign

This high-side current shunt monitor is used to measure the voltage developed across a current-sensing resistor when current passes through it.

Additionally, an external protection circuit is implemented to provide surge and fast-transient protection and demonstrate the different immunity levels to (...)

Unterstützte Produkte und Hardware
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
SOT-SC70 (DCK) 6 Ultra Librarian
UQFN (RSW) 10 Ultra Librarian
SOT-23-THN (DDF) 8 Ultra Librarian

Bestellen & Qualität

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videoreihe

Alle Videos anzeigen

Videos