Produktdetails

Vrwm (V) 33 Bi-/uni-directional Bi-directional Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 1100 IEC 61000-4-5 (A) 27 Breakdown voltage (min) (V) 34.4 Number of channels 1 IO capacitance (typ) (pF) 54 Clamping voltage (V) 40
Vrwm (V) 33 Bi-/uni-directional Bi-directional Package name DFN3030 Peak pulse power (8/20 μs) (max) (W) 1100 IEC 61000-4-5 (A) 27 Breakdown voltage (min) (V) 34.4 Number of channels 1 IO capacitance (typ) (pF) 54 Clamping voltage (V) 40
VSON (DRB) 8 9 mm² 3 x 3
  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A 8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection
  • Functional Safety-Capable
  • Protection against 1-kV, 42-Ω IEC 61000-4-5 surge test for industrial signal lines
  • Bidirectional polarity enables protection against bipolar signaling or miswiring conditions
  • Clamping voltage of 40 V at 27-A of 8/20-µs surge current
  • Standoff voltage: ±33 V
  • Small 3 mm × 3 mm SON footprint
  • Survives over 5,000 repetitive strikes of 25-A 8/20-µs surge current
  • Robust surge protection
    • IEC61000-4-5 (8/20 µs): 27 A
    • IEC61643-321 (10/1000 µs): 3 A
  • Low leakage current
    • 2.5-nA typical at 27°C
    • 450-nA maximum at 85°C
  • Low capacitance: 54 pF
  • Integrated level 4 IEC 61000-4-2 ESD protection

The TVS3301 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS3301 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS3301 has a ±33-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS3301 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3301 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS3301 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

The TVS3301 device shunts up to 27 A of IEC 61000-4-5 fault current to protect systems from high-power transients or lightning strikes. The device survives the common industrial signal line EMC requirement of 1-kV IEC 61000-4-5 open circuit voltage coupled through a 42-Ω impedance. The TVS3301 uses a feedback mechanism to ensure precise flat clamping during a fault, keeping system exposure lower than traditional TVS diodes. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness. The TVS3301 has a ±33-V operating range to enable operation in systems that require protection against reverse wiring conditions.

In addition, the TVS3301 is available in a small SON footprint designed for space constrained applications, offering a significant size reduction compared to standard SMA and SMB packages. Low device leakage and capacitance ensure a minimal effect on the protected line. To ensure robust protection over the lifetime of the product, TI tests the TVS3301 against 5000 repetitive surge strikes at 125°C with no shift in device performance.

The TVS3301 is part of TI’s Flat-Clamp family of surge devices. For a deeper look at the Flat-Clamp family, refer to the Flat-Clamp Surge Protection Technology for Efficient System Protection white paper.

Herunterladen Video mit Transkript ansehen Video

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 14
Typ Titel Datum
* Data sheet TVS3301 33-V Bidirectional Flat-Clamp Surge Protection Device datasheet (Rev. B) PDF | HTML 01 Sep 2022
Circuit design Output Overvoltage Protection Circuit for Voltage DACs With an External Feedback Pin PDF | HTML 29 Jul 2025
Circuit design Output Overvoltage Protection Circuit for Voltage DACs Without an External Feedback Pin PDF | HTML 18 Jun 2025
Analog Design Journal Designing 4mA to 20mA loop-powered transmitters PDF | HTML 28 Mai 2024
Analog Design Journal How to use an ideal diode controller as a scalable input bypass switch in solar applications PDF | HTML 28 Mai 2024
Application note ESD Packaging and Layout Guide (Rev. B) PDF | HTML 18 Aug 2022
Functional safety information TVS3301 Functional Safety, FIT Rate, Failure Mode Distribution and Pin FMA PDF | HTML 27 Sep 2021
Application brief 16-Bit 8-Channel PLC Analog Input Module with High Voltage (±150 V) Common Mode 27 Apr 2020
Application brief Protecting I/O modules from surge events 04 Feb 2019
Application brief TVS Surge Rating: Power vs. Current 12 Nov 2018
White paper Demystifying surge protection 06 Nov 2018
User guide Flat Clamp TVS Evaluation Module—Adaptor Boards 10 Sep 2018
Application note How to select a Surge Diode 29 Aug 2018
Analog Design Journal Design Considerations for System-Level ESD Circuit Protection 25 Sep 2012

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

FLAT-CLAMP-TVS-EVM — TVSxx0x Evaluierungsmodul für Präzisions-Überspannungsschutzdiode

Das FLAT-CLAMP-TVS-EVM (Evaluierungsmodul für Präzisions-Überspannungsschutzdioden-Adapterplatine) zeigt die Eigenschaften, den Betrieb und die Verwendung der Bausteinfamilie TVSxx0x. Die Bausteinfamilie TVSxx0x besteht aus Präzisionsklemmen, die extrem niedrige und flache Klemmspannungen bei (...)
Benutzerhandbuch: PDF
Simulationsmodell

TVS3301 PSpice Transient Model

SLVMCV9.ZIP (52 KB) - PSpice Model
Referenzdesigns

TIDA-010982 — Referenzdesign für Feldtransmitter-Plattform, schleifengespeiste Schnittstelle von 4 mA bis 20 mA

Dieses Referenzdesign zeigt eine Beispielimplementierung einer 4–20 mA-Schnittstelle für schleifengespeiste Zweidraht-Sensoren. Das Design ermöglicht die Evaluierung von AFE881H1 und AFE882H1 in einer anwendungsähnlichen Umgebung mit einer 1,8-V-Signalkette mit geringerer Leistung. Die Bausteine (...)
Design guide: PDF
Referenzdesigns

TIDA-010072 — Referenzdesign zur Luftstrom- und Ventilsteuerung für Beatmungsanwendungen

Dieses Referenzdesign bietet ein kompaktes Systemdesign, das eine Motorbeschleunigung und -verzögerung von bis zu ± 200 kU/min unterstützt, was eine wichtige Anforderung in vielen Atemschutzanwendungen darstellt. Das Design unterstützt eine Reihe von Offboard-C2000-Controllern, darunter den (...)
Design guide: PDF
Schaltplan: PDF
Referenzdesigns

TIDA-010008 — Referenzdesign auf Basis von Flachklemmen-TVS zum Schutz vor Transienten für Stromnetzanwendungen

Dieses Referenzdesign bietet mehrere Ansätze zum Schutz des analogen AC- oder DC-Eingangs, des analogen DC-Ausgangs, des binären AC- oder DC-Eingangs, des digitalen Ausgangs mit einem Highside- oder Low-Side-Treiber, der LCD-Vorspannung, der USB-Schnittstellen (Strom und Daten) und der auf der (...)
Design guide: PDF
Schaltplan: PDF
Referenzdesigns

TIDA-010044 — NAMUR PLC Digitaler Eingang mit Fehlerschutz und Diagnose Referenzdesign

Der NAMUR-Näherungssensor wird häufig in der Industriesteuerung eingesetzt, wenn eine spezielle Anforderung an maximale Energie durch den Sensor erfüllt werden soll. Dies wiederum erfordert besondere Anforderungen an den PLC-Digital-Eingang, der als Schnittstelle zu einem solchen Sensor (...)
Design guide: PDF
Schaltplan: PDF
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
VSON (DRB) 8 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos