If any enabled lane detects one of the following conditions, the JESD controller
asserts SYNC to restart the link.
- JESD_RST = 1
- The rising edge of SYS_EN
- Transmitter sends 4 successive /K/ characters after the start of the ILAS.
- Gearbox overflow/underflow occurs and GBRST_EN=1
- Code group synchronization is lost as specified in 8.6.1 of the JESD204C
spec.
- Two frame/multi-frame alignment characters in unexpected position as specified
in Frame & Multi-frame Monitoring
- The JESD204C link layer exits any sleep mode (via changes to MODE)
- SYSREF causes clock or LMFC realignment
- An elastic buffer error is detected