SLIS187C June 2021 – March 2022 TLC6A598
PRODUCTION DATA
Fault readback is shown in Table 8-6 and described in Table 8-7.
23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
---|---|---|---|---|---|---|---|
DRAIN7_OCP | DRAIN6_OCP | DRAIN5_OCP | DRAIN4_OCP | DRAIN3_OCP | DRAIN2_OCP | DRAIN1_OCP | DRAIN0_OCP |
RC-0h | RC-0h | RC-0h | RC-0h | RC-0h | RC-0h | RC-0h | RC-0h |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
DRAIN7_OorS | DRAIN6_OorS | DRAIN5_OorS | DRAIN4_OorS | DRAIN3_OorS | DRAIN2_OorS | DRAIN1_OorS | DRAIN0_OorS |
RC-0h | RC-0h | RC-0h | RC-0h | RC-0h | RC-0h | RC-0h | RC-0h |
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
TBD | TSD | CRC | |||||
RC-0h | RC-0h | RC-0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
23 | DRAIN7_OCP | RC | 0h |
|
22 | DRAIN6_OCP | RC | 0h |
|
21 | DRAIN5_OCP | RC | 0h |
|
20 | DRAIN4_OCP | RC | 0h |
|
19 | DRAIN3_OCP | RC | 0h |
|
18 | DRAIN2_OCP | RC | 0h |
|
17 | DRAIN1_OCP | RC | 0h |
|
16 | DRAIN0_OCP | RC | 0h |
|
15 | DRAIN7_OorS | RC | 0h |
|
14 | DRAIN6_OorS | RC | 0h |
|
13 | DRAIN5_OorS | RC | 0h |
|
12 | DRAIN4_OorS | RC | 0h |
|
11 | DRAIN3_OorS | RC | 0h |
|
10 | DRAIN2_OorS | RC | 0h |
|
9 | DRAIN1_OorS | RC | 0h |
|
8 | DRAIN0_OorS | RC | 0h |
|
7 | TBD | RC | 0h | TBD |
6 | TSD | RC | 0h |
|
5 | CRC | R | 0h | CRC checksum of configuration registers |
4 | ||||
3 | ||||
2 | ||||
1 | ||||
0 |