SLOS970B January 2018 – January 2025 TPA6404-Q1
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
After performing the phase reference measurements, measure the phase of the speaker load. This is performed in the same manner as the reference measurements, except the loopback is disabled in bit 7 register 0x16. Previously, the phase reference is measured on channel 1 and channel 3 and in this test stage; all four channels will be measured. Measure the channels sequentially as they cannot be measured at the same time.
When the test is complete the channel reporting register indicates the status change from the AC diagnostic mode to the Hi-Z state. The detected phase is stored in the appropriate I2C register when the device transitions to the Hi-Z state.
The AC phase in degrees is calculated with the following equation:
Figure 7-4 AC Phase CalculationWhere:
Phase_CHx(LBK) is the reference phase measurement
Phase_CHx(LDM) is the phase measure of the load
STI_CHx(LDM) is the stimulus value