SLOS970B January   2018  – January 2025 TPA6404-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Typical Characteristics
  7. Parameter measurement Information
  8. Detailed description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Differential Analog inputs
      2. 7.3.2 Gain Control and AC-Coupling
      3. 7.3.3 High-Frequency Pulse-Width Modulator (PWM)
      4. 7.3.4 Gate Drive
      5. 7.3.5 Power FETs
      6. 7.3.6 Load Diagnostics
        1. 7.3.6.1 DC Load Diagnostics
          1. 7.3.6.1.1 Automatic DC Load Diagnostics
          2. 7.3.6.1.2 I2C Controlled DC Load Diagnostics
        2. 7.3.6.2 Line Output Diagnostics
        3. 7.3.6.3 AC Load Diagnostics
          1. 7.3.6.3.1 Impedance Phase Reference Measurement
          2. 7.3.6.3.2 Impedance Phase Measurement
          3. 7.3.6.3.3 Impedance Magnitude Measurement
      7. 7.3.7 Protection and Monitoring
        1. 7.3.7.1 Over current Limit (ILIMIT)
        2. 7.3.7.2 Over current Shutdown (ISD)
        3. 7.3.7.3 DC Detect
        4. 7.3.7.4 Clip Detect
        5. 7.3.7.5 Global Over Temperature Warning (OTW), Over Temperature Shutdown (OTSD) and Thermal Foldback (TFB)
        6. 7.3.7.6 Channel Over Temperature Warning [OTW(i)] and Shutdown [OTSD(i)]
        7. 7.3.7.7 Thermal Foldback
        8. 7.3.7.8 Undervoltage (UV) and Power-On-Reset (POR)
        9. 7.3.7.9 Over Voltage (OV) and Load Dump
      8. 7.3.8 Power Supply
        1. 7.3.8.1 Power-Supply Sequence
      9. 7.3.9 Hardware Control Pins
        1. 7.3.9.1 FAULT
        2. 7.3.9.2 WARN
        3. 7.3.9.3 MUTE
        4. 7.3.9.4 STANDBY
    4. 7.4 Device Functional Modes
      1. 7.4.1 Operating Modes and Faults
    5. 7.5 Programming
      1. 7.5.1 I2C Serial Communication Bus
      2. 7.5.2 I2C Bus Protocol
      3. 7.5.3 Random Write
      4. 7.5.4 Sequential Write
      5. 7.5.5 Random Read
      6. 7.5.6 Sequential Read
  9. Registers
    1. 8.1 Register Maps
      1. 8.1.1  Mode Control Register (address = 0x00) [default = 0x00]
      2. 8.1.2  Miscellaneous Control 1 Register (address = 0x01) [default = 0x32]
      3. 8.1.3  Miscellaneous Control 2 Register (address = 0x02) [default = 0x62]
      4. 8.1.4  Channel State Control Register (address = 0x04) [default = 0x55]
      5. 8.1.5  DC Load Diagnostic Control 1 Register (address = 0x09) [default = 0x00]
      6. 8.1.6  DC Load Diagnostic Control 2 Register (address = 0x0A) [default = 0x11]
      7. 8.1.7  DC Load Diagnostic Control 3 Register (address = 0x0B) [default = 0x11]
      8. 8.1.8  DC Load Diagnostic Report 1 Register (address = 0x0C) [default = 0x00]
      9. 8.1.9  DC Load Diagnostic Report 2 Register (address = 0x0D) [default = 0x00]
      10. 8.1.10 DC Load Diagnostics Report 3—Line Output—Register (address = 0x0E) [default = 0x00]
      11. 8.1.11 Channel State Reporting Register (address = 0x0F) [default = 0x55]
      12. 8.1.12 Channel Faults (Over current, DC Detection) Register (address = 0x10) [default = 0x00]
      13. 8.1.13 Global Faults 1 Register (address = 0x11) [default = 0x00]
      14. 8.1.14 Global Faults 2 Register (address = 0x12) [default = 0x00]
      15. 8.1.15 Warnings Register (address = 0x13) [default = 0x20]
      16. 8.1.16 Pin Control Register (address = 0x14) [default = 0x00]
      17. 8.1.17 AC Load Diagnostic Control 1 Register (address = 0x15) [default = 0x00]
      18. 8.1.18 AC Load Diagnostic Control 2 Register (address = 0x16) [default = 0x00]
      19. 8.1.19 AC Load Diagnostic Report Ch1 through CH4 Registers (address = 0x17–0x1A) [default = 0x00]
      20. 8.1.20 AC Load Diagnostic Report Phase High Register (address = 0x1B) [default = 0x00]
      21. 8.1.21 AC Load Diagnostic Report Phase Low Register (address = 0x1C) [default = 0x00]
      22. 8.1.22 AC Load Diagnostic Report STI High Register (address = 0x1D) [default = 0x00]
      23. 8.1.23 AC Load Diagnostic Report STI Low Register (address = 0x1E) [default = 0x00]
      24. 8.1.24 Miscellaneous Control 3 Register (address = 0x21) [default = 0x00]
      25. 8.1.25 Clip Control Register (address = 0x22) [default = 0x01]
      26. 8.1.26 Clip Warning Register (address = 0x24) [default = 0x00]
      27. 8.1.27 Current LIMIT Status Register (address = 0x25) [default = 0x00]
      28. 8.1.28 Fault and Warning Pin Control Register (address = 0x27) [default = 0x7F]
      29. 8.1.29 Thermal Foldback Control Register (address = 0x28) [default = 0x00]
      30. 8.1.30 AC Diagnostic Frequency Control Register (address = 0x2A) [default = 0x32]
      31. 8.1.31 SYNC PIN Control Register (address = 0x2B) [default = 0x02]
  10. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 AM Radio Avoidance
      2. 9.1.2 Parallel BTL Operation (PBTL)
      3. 9.1.3 Reconstruction Filter Design
      4. 9.1.4 Line Driver Applications
    2. 9.2 Typical Applications
      1. 9.2.1 BTL Application
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1 Hardware Design
          2. 9.2.1.2.2 Bootstrap Capacitors
          3. 9.2.1.2.3 Output Reconstruction Filter
        3. 9.2.1.3 Application Curves
        4. 9.2.1.4 PBTL Application
          1. 9.2.1.4.1 Design Requirements
          2. 9.2.1.4.2 Detailed Design Procedure
            1. 9.2.1.4.2.1 Hardware Design
          3. 9.2.1.4.3 Application Curves
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
        1. 9.4.1.1 Electrical Connection of Thermal pad and Heat Sink
        2. 9.4.1.2 EMI Considerations
        3. 9.4.1.3 General Considerations
      2. 9.4.2 Layout Example
      3. 9.4.3 Thermal Considerations
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Electrostatic Discharge Caution
    4. 10.4 Glossary
    5. 10.5 Support Resources
    6. 10.6 Trademarks
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information
    1. 12.1 Package Option Addendum
      1. 12.1.1 Packaging Information
      2. 12.1.2 Tape and Reel Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DKQ|56
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Packaging Information

Orderable DeviceStatus (1)Package TypePackage DrawingPinsPackage QtyEco Plan (2)Lead/Ball Finish(4)MSL Peak Temp (3)Op Temp (°C)Device Marking(5)(6)
TPA6404QDKQRQ1ACTIVEHSSOPDKQ561000Green (RoHS & no Sb/Br)CU NIPDAULevel-3-260C-168 HR-40 to 125TPA6404
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PRE_PROD Unannounced device, not in production, not available for mass market, nor on the web, samples not available.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width.
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device
Multiple Device markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device.
Important Information and Disclaimer: The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.