SBOS790A April 2017 – March 2025 INA233
PRODUCTION DATA
This register configures various behaviors of the device in regards to data communications and alerts.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| EIN_STATUS | Reserved | EIN_ACCUM | I2C_FILT | READ_EIN Autoclear | Alert Behavior | APOL | |
| R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-1 | R/W-0 | |
| Bit | Field | Type | Default | Description |
|---|---|---|---|---|
| 7 | EIN_STATUS | R/W | 0 | 0 = All values added to the EIN accumulator match the setting of EIN_ACCUM 1 = The EIN accumulator encountered a value inconsistent with the selected mode of operation. For EIN_ACCUM = 01, a negative value of the sign bit of READ_IIN is detected. For EIN_ACCUM = 10, a positive value of the sign bit of READ_IIN is detected. EIN_STATUS is not set when EIN_ACCUM is 00 or 11. |
| 6 | Reserved | R/W | 0 | Reserved |
| 5:4 | EIN_ACCUM | R/W | 00 | 00, 11 = The READ_EIN accumulator sums all values of the
READ_POUT register. Both negative and currents increase the
accumulator. 01 = The READ_EIN only sums positive values of the READ_POUT register based on the sign bit of the READ_IIN register; the sample count continues to increment for negative values 10 = The READ_EIN only sums negative values of the READ_POUT register based on the sign bit of the READ_IIN register; the sample count continues to increment for positive values |
| 3 | I2C_FILT | R/W | 0 | 0 = Normal operation 1 = Disables the I2C input filter |
| 2 | READ_EIN Autoclear | R/W | 0 | 0 = Does not clear the sample count and accumulator 1 = Clears the sample count and accumulator after read |
| 1 | Alert Behavior | R/W | 1 | 0 = Transparent 1 = Latched |
| 0 | APOL | R/W | 0 | Alert polarity bit. 0 = Normal 1 = Inverted |