STATUS_MFR_SPECIFIC is a standard PMBus command that contains manufacturer-specific status information. Use the PMBus read byte protocol to access this command. To clear bits in this register, clear the underlying fault and issue a CLEAR_FAULTS command or write a 1 to the bit to be cleared. Table 6-15 lists the definitions for this command.
| BIT | MEANING | DEFAULT |
|---|---|---|
| 7 | Conversion ready | 0 |
| 6 | Arithmetic overflow flag. If the bit is set to 1 then an arithmetic operation results from an overflow error. This bit indicates that either the current or power data is invalid. | 0 |
| 5 | Power-on-reset event detected. To detect power-on or power glitch events, this bit must be cleared after initial power up. If power is interrupted this bit is reset to the default value of 1. | 1 |
| 4 | Communications or memory fault (or of STATUS_CML) | 0 |
| 3 | Input overpower warning | 0 |
| 2 | Input overcurrent warning | 0 |
| 1 | Input overvoltage warning | 0 |
| 0 | Input undervoltage warning | 0 |