SBOS790A April 2017 – March 2025 INA233
PRODUCTION DATA
STATUS_INPUT is a standard PMBus command that returns the value of the of a number of flags related to input voltage, current, and power. Use the PMBus read byte protocol to access this command. To clear bits in this register, clear the underlying fault and issue a CLEAR_FAULTS command or write a 1 to the bit to be cleared. Table 6-13 lists the definitions for this command.
| BIT | NAME | MEANING | DEFAULT |
|---|---|---|---|
| 7 | VIN_OV fault | Not supported | 0 |
| 6 | VIN_OV_WARN | An input overvoltage warning has occurred | 0 |
| 5 | VIN_UV_WARN | An input undervoltage warning has occurred | 0 |
| 4 | VIN_UV fault | Not supported | 0 |
| 3 | Insufficient voltage | Not supported | 0 |
| 2 | IIN_OC fault | Not supported | 0 |
| 1 | IIN_OC_WARN | An input overcurrent warning has occurred | 0 |
| 0 | PIN_OP_WARN | An input overpower warning has occurred | 0 |