SBOS790A April 2017 – March 2025 INA233
PRODUCTION DATA
VIN_OV_WARN_LIMIT is a standard PMBus command that allows configuring or reading the threshold for a VBUS overvoltage warning detection. Use the coefficients listed in Table 6-1 when reading and writing to this register. Use the PMBus read or write word protocol to access this command.
When this input overvoltage warning limit is exceeded, the device:
This fault is masked with the MFR_ALERT_MASK command using the VIN_OV_WARNING
See the Reading and Writing Telemetry Data and Warning Thresholds and Writing Telemetry Data and Warning Thresholds sections for additional information on reading and setting warning thresholds.
Full-scale range = 40.96 V (7FFFh) and LSB = 1.25 mV.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| — | V11 | V10 | V9 | V8 | V7 | V6 | V5 |
| R-0 | R/W-1 | R/W-1 | R/W-1 | R/W-1 | R/W-1 | R/W-1 | R/W-1 |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| V4 | V3 | V2 | V1 | V0 | — | — | — |
| R/W-1 | R/W-1 | R/W-1 | R/W-1 | R/W-1 | R-0 | R-0 | R-0 |
| Bit | Field | Type | Default | Description |
|---|---|---|---|---|
| 15 | — | R | 0 | Reserved; always 0. |
| 14:3 | V[11:0] | R/W | 1 | These bits control the VIN_OV_WARN_LIMIT. The bit weightings in this register match the bit weightings in the READ_VIN register (V0 = BV3). |
| 2:0 | — | R/W | 0 | Reserved; always 0. |