SDAA370 May   2026 UCC34141

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
    1. 1.1 End-Equipment Traction Inverter
    2. 1.2 Why is Safety Needed in Inverter?
    3. 1.3 FuSa Development Flow
      1. 1.3.1 V-Model Development
      2. 1.3.2 Inverter Safety Lifecycle
  5. 2FuSa Requirements for Traction Inverter
    1. 2.1 Traction Inverter Structure and Function Introduction
    2. 2.2 FuSa Requirements Derivation Process
    3. 2.3 Safety Goal
    4. 2.4 FuSa Concept
      1. 2.4.1 FSC Design Architecture
      2. 2.4.2 Fault Tree Analysis
      3. 2.4.3 FuSa Requirement
    5. 2.5 Technical Safety Concepts
      1. 2.5.1 TSC Design Architecture
      2. 2.5.2 Failure Mode and Effect Analysis
      3. 2.5.3 Technical Safety Requirements
  6. 3Safety Design Implementation on Inverter
    1. 3.1 TI FuSa Product
    2. 3.2 How Does TSR Implement?
      1. 3.2.1 Position Sensor
      2. 3.2.2 MCU
      3. 3.2.3 Logic Circuit
      4. 3.2.4 Smart Isolated Gate Driver
    3. 3.3 Dependent Failure Consideration
    4. 3.4 Detailed FuSa Design Structure for Traction Inverter
    5. 3.5 Achieving FuSa Requirements with TI Safety Devices
      1. 3.5.1 MCU
      2. 3.5.2 Gate Driver
        1. 3.5.2.1 Gate Monitor Circuit and Over Current Protection
        2. 3.5.2.2 Other Safety Mechanisms in UCC5881-Q1
      3. 3.5.3 Isolated bias supply
        1. 3.5.3.1 Centralized LV Isolated Power Supply Architecture
        2. 3.5.3.2 Fully Distributed LV Isolated Power Supply Architecture
        3. 3.5.3.3 Semi-Distributed LV Isolated Power Supply Architecture
        4. 3.5.3.4 HV Isolated Bias Supply
        5. 3.5.3.5 TI's Design for Isolated Bias Supply in Traction Inverter
      4. 3.5.4 Power Management IC
        1. 3.5.4.1 Multiple Paths Power Rail with Protection and Independent Thermal Shut-Down
        2. 3.5.4.2 Power Rail Voltage Monitoring
        3. 3.5.4.3 MCU Fault Monitor and other Protection Mechanisms
      5. 3.5.5 Position Sensor
      6. 3.5.6 Current Sensor
      7. 3.5.7 Voltage Sensor
        1. 3.5.7.1 Isolated DC Voltage Sensing
        2. 3.5.7.2 Non-Isolated DC voltage sensing
      8. 3.5.8 Temperature Sensor
  7. 4Summary
  8. 5References

FuSa Requirement

From the FTA results, certain failures were identified as first-order cut-sets that directly violate the top safety goal, causing unintended torque and potential damage. For example, if GT15 – the motor position sensor output a wrong position signal is TRUE, the MCU will receive incorrect position signal from sensor for FOC control, triggering events GT10 and GT7. This will cause the FOC algorithm to output incorrect PWM signals, generating wrong AC current and torque, ultimately leading to the top event TP1-provide unintended accelerating torque than expected.

Based on this analysis, the user can propose an FSR such as Inverter shall correctly measure rotor position by position sensor and assign this requirement to the motor position sensor implementation. Using this methodical approach,all first order and second order cut-sets into FSRs under the safety goal Avoid unintended accelerating torque than expected have been derived, as listed in Table 2-3.

Table 2-3 Example FSRs for SG1
FSR ID FuSa Requirement Safe State Allocation ASIL FTTI Traced to
1.1 Inverter shall correctly transfer the communication data from VCU to MCU with the interface circuit. Generate alert to MCU. Enter 0-torque control. HW, E5
SW, E4
HW&SW
D FTTI GT5
1.2 Inverter shall correctly provide the power supply for the interface circuit. Enter 0-torque control. HW, E7, E5
SW, E4
HW&SW
D FTTI GT6
1.3 Inverter shall correctly perform communication command decode from VCU by MCU. Discard torque command and enter 0-torque control. HW, E4, E5
SW, E4
HW&SW
D FTTI GT4
1.4 Inverter shall correctly measure motor phase currents by current sensor. Generate alert to MCU. Enter ASC or freewheeling. HW, E1
SW, E4
HW&SW
D FTTI GT13
1.5 Inverter shall correctly provide the power supply for current sensor. Generate alert to MCU. Enter ASC or freewheeling. HW, E7
SW, E4
HW&SW
D FTTI GT14
1.6 Inverter shall correctly measure rotor position by position sensor. Generate alert to MCU. Enter ASC or freewheeling. HW, E2
SW, E4
HW&SW
D FTTI GT15
1.7 Inverter shall correctly provide the power supply for position sensor. Generate alert to MCU. Enter ASC or freewheeling. HW, E7
SW, E4
HW&SW
D FTTI GT16
1.8 Inverter shall correctly measure the HV battery voltage by voltage sensor. Generate alert to MCU. Enter ASC or freewheeling. HW, E3
SW, E4
HW&SW
D FTTI GT18
1.9 Inverter shall correctly provide the power supply for voltage sensor. Generate alert to MCU. Enter ASC or freewheeling. HW, E7
SW, E4
HW&SW
D FTTI GT19
1.10 Inverter shall correctly provide the isolated power supply for voltage sensor. Generate alert to MCU. Enter ASC or freewheeling. HW, E7, E11
SW, E4
HW&SW
D FTTI GT20
1.11 Inverter shall correctly perform power module temperature measurement. Generate alert to MCU. Limit the maximum torque. HW, E12
SW, E4
HW&SW
D MPFDTI GT21
1.12 Inverter shall correctly support motor control software algorithm run in MCU. Block MCU output. Enter ASC or freewheeling. HW, E4, E5
SW, E4
HW&SW
D FTTI GT22
1.13 Inverter shall correctly provide PWM control signal output from MCU.

Block MCU PWM output.

Enter ASC or freewheeling.

HW, E4, E5
SW, E4
HW&SW
D FTTI GT23
1.14 Inverter shall correctly provide the power supply for MCU.

Reset MCU.

Enter ASC or freewheeling.

HW, E7, E5
SW, E4
HW&SW
D FTTI GT30
1.15 Inverter shall correctly amplify the PWM signal into driving signal in gate driver. Generate alert to MCU. Enter ASC or freewheeling. HW, E6
SW, E4
HW&SW
D FTTI GT25
1.16 Inverter shall correctly provide the power supply for the gate driver. Generate alert to MCU. Enter ASC or freewheeling. HW, E7, E6
SW, E4
HW&SW
D FTTI GT26
1.17 Inverter shall correctly provide the isolated power supply for the gate driver HV side. Generate alert to MCU. Enter ASC or freewheeling. HW, E7, E6
SW, E4
HW&SW
D FTTI GT27
1.18 Inverter shall correctly perform activation/deactivation control by power stage. Generate alert to MCU. Enter ASC or freewheeling. HW, E6, E10
SW, E4
HW&SW
D FTTI GT28

As shown in Table 2-3, there are several failure modes that directly violate the top safety goal. The system needs to be forced into a safety state after a failure occurs. Considering the traction inverter with PMSM, which generates a significant back-EMF at high speed. We have defined four possible safe states:

  • Degrade to 0-torque mode

This is the safe state when the traction inverter can still provide fully motor control and sensing functions. The MCU continues to run the FOC algorithm based on sensing signals with iq = 0 for zero torque output. This safe state is appropriate for communication failures, such as receiving incorrect VCU commands or harness disconnection. Since other parts of the inverter remain operational, normal function can be easily restored when the failure is resolved.

  • Freewheeling

This is the safe state when the traction inverter cannot generate correct AC currents and torque following commands at low speed. All power switches are turned off in this safe state to disconnect all three phases. At low motor speed, the PMSM will only generate back-EMF lower than the HV battery voltage.

  • Active short circuit (ASC)

This is the safe state when the traction inverter cannot generate correct AC current and torque following commands at high speed. At high speeds, the PMSM generates back-EMF greater than the HV battery voltage, causing significant regeneration current, excessive braking torque, and potential battery damage. Therefore, the inverter should enter ASC at high speeds by turning on either all three high-side power switches or all three low-side power switches to short the three phases. This limits the phase current to a constant value with low braking torque.

  • Limit torque output

This is a degraded fail-operational strategy implemented when the power module temperature exceeds an alert threshold. If the temperature continues to rise above the shutdown threshold despite running in this degraded mode, the traction inverter enters either ASC or freewheeling mode.