Beyond the gate monitoring and over-current protection features,
the UCC5881-Q1 incorporates numerous additional safety mechanisms
designed to enhance traction inverter protection and fault
reporting capabilities:
- Vgs(th) power module healthy status checking at start-up
state.
- Undervoltage and overvoltage monitoring on VCC1, VCC2, and VEE2
power supplies
- Undervoltage and overvoltage monitoring on internal power
supplies used for its supporting circuits
- Clock monitor on logic clock
- Configuration Data Cyclic Redundancy Check (CRC)
- SPI CRC
- Internal NVM (non-volatile memory) CRC
- Built-in self-test (BIST) diagnostics for VCC1, VCC2, VEE2, and
internal regulator UV/OV monitoring functions, and main clocks
- Power transistor high voltage clamping circuit detection and
function diagnostics
- Active Miller clamp diagnostic.