Dependent Failure Analysis (DFA) is a systematic safety analysis methodology designed to identify and evaluate common cause failures or cascading failures that could lead to simultaneous failures of multiple components within a system. The core principle of DFA involves analyzing interdependence within the system to identify initiators that can cause multiple safety functions fail simultaneously, such as environmental factors, design flaws, manufacturing process issues, external interference, etc.
The main process of DFA follows four key steps:
Due to space limitations, Table 3-2 shows only a portion of the DFA analysis for the traction inverter system, focusing on the position sensor subsystem.
| Element | Dependent Element | DFI Type | DFI Root Cause | DFI Effect | Fault Prevention Measures | Fault Control Measures |
|---|---|---|---|---|---|---|
|
#1 LDC5073-Q1 |
#2 LDC5073-Q1 |
Failure of shared resources | Shared power | The share 3.3V power can lead #1 LDC5073-Q1 and #2 LDC5073-Q1 loss of function at the same time | PMIC TPS65386x-Q1 3.3V LDO embedded with output voltage monitoring for UV, OV, SC events. |
|
| Shared power supply elements | The failure of PMIC can lead #1 LDC5073-Q1 and #2 LDC5073-Q1 loss of function at the same time | TPS65386-Q1 equipped with multiple safety mechanisms like BIST, UVLO, VMON, CRC, etc. can cover the failures of PMIC |
|
|||
| Single physical root cause | Cross talk | The location of position sensor can affect by cross talk and lead #1 LDC5073-Q1 and #2 LDC5073-Q1 loss of function at the same time | NA | Simulation and validation testing to verify performance. | ||
| Local heating | The location of position sensor can affect by heating and lead #1 LDC5073-Q1 and #2 LDC5073-Q1 loss of function at the same time | NA |
|
|||
| Environmental faults | EMI | For some application scenarios, both #1 LDC5073-Q1 and #2 LDC5073-Q1 can be affected and loss of function at the same time | NA | Integration testing by customers | ||
| ESD | The position sensor location can be affected by ESD and lead #1 LDC5073-Q1 and #2 LDC5073-Q1 loss of function at the same time | ESD protection design for specific boundaries. | ESD limits are defined in spec and ESD tests are performed on all pins according to the ESD standard |
In our traction inverter system FuSa design, DFA analysis methodology has been comprehensively implemented. As a result, diversified redundancy, physical isolation, independent monitoring, and other protective measures have been implemented in our design to make sure the system can maintain necessary safety functions when facing common cause failures. These measures significantly enhance the FuSa level and reliability of the traction inverter system.
The systematic approach to dependent failure analysis makes sure that potential common cause failures are identified early in the design process and appropriate countermeasures are implemented, preventing simultaneous failures that can compromise the overall safety of the traction inverter system.