SDAA370 May 2026 UCC34141
Once the FSC has been established, the subsequent phase is to create the Technical Safety Concept (TSC). The TSC translates the FSCs into concrete TSRs. FuSa analysis is used to derive these technical safety requirements from FSRs.
In the previous chapter, this document showed how to perform FTA for the traction inverter system. This chapter uses FMEA, a representative inductive analysis method, to illustrate the safety analysis process and how to derive TSRs. This chapter uses FSR1.6 – Inverter shall correctly measure rotor position by position sensor as the example for this demonstration.
FMEA is a systematic methodology that identifies possible failure modes in product designs, evaluates their effects and causes, and develops appropriate preventive and control measures targeting each specific failure. Unlike FTA, which works top-down from a defined hazard, FMEA works bottom-up by examining individual components and their potential failure modes, then tracing the consequences up to system-level effects.