SPRAD57 August   2022 TDA4VM

 

  1.   Abstract
  2.   Trademarks
  3. 1Jacinto™ 7 Safety Architecture Concepts
    1. 1.1 Safety Architectural Overview: MCU Island and Extended MCU Island
    2. 1.2 Implementing Mixed Criticality - Freedom from Interference (FFI)
  4. 2Overview of Safety Mechanisms
  5. 3Implementation of Safety in Your System
    1. 3.1 Hardware Collateral
    2. 3.2 Software Support

Software Support

To enable customers on their safety journey, TI provides a ASIL-D/SIL-3 safety assessed Software Diagnostic Library (SDL) that covers system level diagnostics and safety features. The SDL is a collection of initialization/configuration, self-test, runtime, and response handler APIs that support various safety mechanisms. It is a fully self-contained library with no dependency on external software and provides an OS Abstraction Layer (OSAL) supporting implementation in both OS and non-OS (baremetal) environments. A compliance support package (CSP) is also provided alongside the SDL to support customers in re-qualification efforts on their system.

Both the SDL and CSP can be accessed via mysecuresw and access can be requested here.

Table 3-1 Summary of SDL and CSP Product Deliverables
SDL Supported Functions CSP Deliverables

Diagnostics:Memory BIST, Logic BIST, ECC and Parity, ECC Aggregator, Error Signaling Module, R5F Lockstep (CCM)

Safety Features: Clock Monitor, Voltage Monitors, Temperature Sensors, Timeout/Isolation Gaskets, Watchdog Timers, R5F MPU, PMU, VIM, and RAT Support

  • Requirements, test plan and reports
  • Traceability report
  • Dynamic code coverage analysis report
  • Static code analysis/MISRA-C report
  • User guide with safety manual
  • Software FMEA report