SBOS527G December 2010 – September 2025 TMP411-Q1 , TMP411D-Q1
PRODUCTION DATA
When the TMP411-Q1 and TMP411D-Q1 devices are in Shutdown mode (SD = 1 in the Configuration Register), a single conversion on both channels is started by writing any value to the One-Shot Start Register, pointer address 0Fh. This write operation starts one conversion; the TMP411-Q1 and TMP411D-Q1 return to Shutdown mode when that conversion completes. The value of the data sent in the write command is irrelevant and is not stored by the TMP411-Q1 and TMP411D-Q1. When the TMP411-Q1 and TMP411D-Q1 devices are in Shutdown mode, an initial 200μs is required before a one-shot command can be given. (NOTE: When a shutdown command is issued, the TMP411-Q1 and TMP411D-Q1 complete the current conversion before shutting down.) This wait time only applies to the 200μs immediately following shutdown. One-shot commands can be issued without delay thereafter.