SBASAX3A May 2025 – September 2025 ADS9326 , ADS9327
PRODUCTION DATA
To enable averaging with a non-continuous CONVST, follow the sequence in Table 7-7.
| Step | Description |
|---|---|
| 1 | Unlock the device register map. |
| 2 | Enable simple average by writing 1b to SAVG_EN and selecting the window size in SAVG_MODE. |
| 3 | Write 1b to AVG_SYNC. |
| 4 | Provide 1 pulse of CONVST. |
| 5 | Write 0b to AVG_SYNC. |
| 6 | Provide 2 additional pulses of CONVST. This step is required after toggling AVG_SYNC. |
Figure 7-11 illustrates the timing to enable simple averaging for an average of 2 samples with a noncontinuous CONVST.