SCAS892D February 2010 – July 2025 CDCE937-Q1 , CDCEL937-Q1
PRODUCTION DATA
When the CDCE937-Q1 or CDCEL937-Q1 device is used as a crystal buffer, crystal oscillator start-up dominates the start-up time compared to the internal PLL lock time. Figure 10-4 shows the oscillator start-up sequence for a 27MHz crystal input with an 8pF load. The start-up time for the crystal is on the order of approximately 250µs, compared to approximately 10µs of lock time. In general, lock time is an order of magnitude less than the crystal start-up time.
Figure 10-4 Crystal Oscillator Start-Up vs PLL Lock Time