SLLSFZ8 November 2025 MCF8329HS-Q1
PRODUCTION DATA
MCF8329HS-Q1 provides the option of redundant motor lock detection using a single digital Hall input - this can be enabled by setting HALL_EN to 1b. MCF8329HS-Q1 uses the digital Hall input on HALL_IN pin to detect motor lock condition (in open and closed loop states) and to measure the motor speed; when HALL_SNS_STARTUP_EN is set to 1b, the Hall input is also used to adjust the open loop acceleration rate. If no Hall edge transition is observed on HALL_IN pin for 500ms when HALL_EN is set to 1b and input reference is set to a non-zero value, MCF8329HS-Q1 asserts a motor lock fault and takes protective action as per MTR_LCK_MODE.