SLUSG35A August 2026 – November 2026 TPS12S24F-Q1
ADVANCE INFORMATION
The TPS12SxxF-Q1 device senses SRCx pin voltage and provides an output voltage measurement per channel through the integrated 10-bit ADC. The output voltage measurement function is disabled by default. To enable the output voltage sense function it must be globally enabled in the ADC_CONFIG register through the ADC_VSNS_DIS bit. If the global bit is enabled then the device enables the output voltage measurement on each channel according to the VSNS_DIS_CHx bit in the respective CHx_CONFIG register.