SLUSG35A August   2026  â€“ November 2026 TPS12S24F-Q1

ADVANCE INFORMATION  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Pin Configuration and Functions
  6. 5 Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
    7. 5.7 SPI Timing Requirements
  7. 6 Parameter Measurement Information
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Power Supply Input
      2. 7.3.2 Charge Pump and Gate Driver Output (VS, GATEx, BSTx, SRCx)
      3. 7.3.3 Driving Capacitive, Resistive and Inductive Loads
        1. 7.3.3.1 Capacitive Load Driving
          1. 7.3.3.1.1 Using SCP Based Auto-Retry Method (GATEx):
          2. 7.3.3.1.2 Using Main Path Gate Slew Rate Control Method (GATEx, SRCx):
            1. 7.3.3.1.2.1 Setting the INRUSH Current
            2. 7.3.3.1.2.2 Sizing CBSTx Capacitor
          3. 7.3.3.1.3 Using PWM Control Method (GATEx)
        2. 7.3.3.2 Resistive or Inductive Load Driving
      4. 7.3.4 Protection Mechanisms
        1. 7.3.4.1 I2T Based Overcurrent and Short-Circuit Protection
          1. 7.3.4.1.1 I2T Accumulation and De-Accumulation for DCR_CHx = '0' Setting
          2. 7.3.4.1.2 I2T Accumulation and De-accumulation for DCR_CHx = '1' Setting
        2. 7.3.4.2 NTC-Based External FET Over-Temperature Protection
        3. 7.3.4.3 Device Junction Overtemperature Warning
        4. 7.3.4.4 Input Undervoltage and Overvoltage Protection
        5. 7.3.4.5 External FET Drain to Source Voltage (VDS) Overvoltage Protection
        6. 7.3.4.6 Bi-VDS Based Short-Circuit Protection
        7. 7.3.4.7 Reverse Polarity Protection
        8. 7.3.4.8 Loss of Ground
      5. 7.3.5 Diagnostic Mechanisms
        1. 7.3.5.1 ADC Sense Signals
        2. 7.3.5.2 Analog and Digital Current Monitor (VIMONx)
        3. 7.3.5.3 Input Supply Voltage Measurement
        4. 7.3.5.4 Output Voltage Measurement
        5. 7.3.5.5 External FET Temperature Measurement
        6. 7.3.5.6 External FET Bi-Directional Drain to Source (Bi-VDS) Measurement
        7. 7.3.5.7 Controller Temperature Measurement
        8. 7.3.5.8 VOUT Short-to-Battery or FET Short and Open-Load Detection
          1. 7.3.5.8.1 Measurement With Main FET (GATEx) Enabled
          2. 7.3.5.8.2 Detection With Main FET (GATEx) Disabled
            1. 7.3.5.8.2.1 Off-State Short-to-Battery Detection
            2. 7.3.5.8.2.2 Off-State Open Load Detection
        9. 7.3.5.9 VOUT Short-to-Battery or FET Short Detection for Power at all Times (PAAT) Loads
      6. 7.3.6 Fault Indication (FLT / WAKE)
        1. 7.3.6.1 FAULT_GLOBAL [15:8] Bits
      7. 7.3.7 Output Disable (OUT_DISx) Function
      8. 7.3.8 Brief Supply Interruptions Behavior
        1. 7.3.8.1 EVENT1
        2. 7.3.8.2 EVENT2
      9. 7.3.9 SPI Mode Operation
        1. 7.3.9.1 SPI
        2. 7.3.9.2 Chip Select (CS)
        3. 7.3.9.3 System Clock (SCLK)
        4. 7.3.9.4 Serial Data In (SDI) and Serial Data Out (SDO)
        5. 7.3.9.5 CRC Error Detection and Checking of Clocks
        6. 7.3.9.6 SPI Frame Format
        7. 7.3.9.7 SPI Watchdog Function
    4. 7.4 Device Functional Modes
      1. 7.4.1 State Diagram
      2. 7.4.2 Power Down
      3. 7.4.3 Sleep Mode
      4. 7.4.4 Config or Active Mode (AM)
      5. 7.4.5 Low Power Mode (LPM)
        1. 7.4.5.1 Automatic Low Power Mode (LPM) to Active Mode (AUTO_LPM_ENTRY = '0')
        2. 7.4.5.2 Automatic Low Power Mode (LPM) to Active Mode to LPM (AUTO LPM) for ECU polling (AUTO_LPM_ENTRY = '1')
          1. 7.4.5.2.1 EVENT1
          2. 7.4.5.2.2 EVENT2
          3. 7.4.5.2.3 EVENT3
      6. 7.4.6 Limphome Mode
    5. 7.5 TPS12S24F-Q1 Pre-Production Silicon Limitations
      1. 7.5.1 SDO Pin Tristate Workaround (Only for Parallel SPI Configuration, not for Daisy-Chain)
  9. 8 Register Maps
    1. 8.1 TPS12S24F-Q1 Registers
    2. 8.2 EEPROM (NVM) Overview
  10. 9 Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Driving Power at All Times (PAAT) Loads With Automatic Load Wakeup and Output Bulk Capacitor Charging
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1 Selection of Main Path MOSFETs
          2. 9.2.1.2.2 Selection of Bootstrap Capacitor, CBSTx
        3. 9.2.1.3 Application Curves
    3. 9.3 System Examples
      1. 9.3.1 TPS12S24F-Q1 System Level Configurations
    4. 9.4 Power Supply Recommendations
      1. 9.4.1 Transient and EMI/EMC Recommendations
    5. 9.5 Layout
      1. 9.5.1 Layout Guidelines
      2. 9.5.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Receiving Notification of Documentation Updates
    2. 10.2 Support Resources
    3. 10.3 Trademarks
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information
    1. 12.1 Tape and Reel Information
    2. 12.2 Mechanical Data

I2T Based Overcurrent and Short-Circuit Protection

The device includes a programmable fuse protection for each channel, that is based on a defined time-current curve and is commonly referred to as I2T protection in melting fuse datasheets. The intent is to match the switch turnoff behavior of a melting fuse. The NOM_CUR_CHx bits and I2T_TRIP_CHx bits set the time-current curve and immediate shutdown protection (ISC) to create the full I2T protection for the device. The I2T protection of the device consists of three regions:

The I2T protection of the device consists of three regions:

  1. Nominal current
  2. I2T based Fuse shutdown
  3. Immediate shutdown protection (SCP)

The operational region for the fuse-based shutdown is shown in the Figure 7-10. Exemplary values for the current values that bound the operational region is included.

TPS12S24F-Q1 Configurable Current vs Time
                    Characteristics Curve For TPS12SxxF-Q1 Figure 7-10 Configurable Current vs Time Characteristics Curve For TPS12SxxF-Q1

The nominal current region (1) defines the region where the device can supply current indefinitely without turning off. This is roughly equivalent to the fuse current rating of a melting fuse. This region is set by the NOM_CUR_CHx bits and if the output current is less than the NOM_CUR_CHx setting then the device can supply current indefinitely as previously stated and it does not start the I2T accumulation. If the output current is greater than or equal to the NOM_CUR_CHx setting then the device enters the I2T accumulation loop and starts to accumulate until the I2T_TRIP_CHx threshold is met. If the output current falls back below the NOM_CUR_CHx before the I2T_TRIP_CHx value is reached then the device starts the I2T de-accumulation.

Above the nominal current region, is the fuse shutdown region (2) which is set by the I2T_TRIP_CHx bits. This region defines the curvature of time-current curve and the region where the I2T accumulation of the device is active and where I2T_MOD_CHx is set to 1. Based on the output current level and the NOM_CUR_CHx setting the device trips at different time intervals based on the I2T_TRIP_CHx value that is set. Depending on the DCR_CHx bit in the I2T_CONFIG_CHx register, the time-current curve of the device is defined by the equations in the following sections.