SNVSCO1 November 2025 LM5126A-Q1
PRODUCTION DATA
RC filters are suggested for current sensing. 100pF of CCS and 1Ω of RCSFP, RCSFN are normal recommendations. Place CCS close to the device.
Route CSP and CSN traces together with Kelvin connections to the current sense resistors.
Increase CCS and RCSFN to increase the RC time constant. Increasing RCSFP brings significant current sensing error.