After power-up, the internal registers must be initialized to the default values through a hardware reset by applying a low pulse on the RESET pin, as shown in Figure 8-10. Any given power rail needs to reach 90% of the value before starting the next power rail.
1. Apply 0.9V DVDD09 digital power supply
2. Apply 1.2V AVDD12 and CLKVDD12 power supplies
3. Apply 1.8V power supplies (AVDD18, GPIOVDD18, DVDD18), in no specific order
4. Apply sampling clock
5. Apply hardware reset. After hardware reset is released, the default registers are loaded from internal fuses.
6. Start programming the internal registers using the SPI register writes. The internal calibration starts automatically and a register can be read back to check the status of the calibration.
For power down, the inverse sequence can be followed.
| MIN | TYP | MAX | UNIT | ||
|---|---|---|---|---|---|
| t1 | Power-on delay: delay from power up to active low RESET pulse | 1 | us | ||
| t2 | Reset pulse width: active low RESET pulse width | 100 | ns | ||