SLVSIM8A June 2025 – December 2025 DRV8363-Q1
PRODUCTION DATA
To help systems driving high-intertia loads, or systems that may be exposed to generator-mode conditions (where the motor is being externally turned), the DRV8363-Q1 incorporates an advanced Active Short Circuit feature. This feature, which can be triggered through the ASCIN pin, through SPI, or automatically in response to VDRAIN Overvoltage, turns on all three high-side or all three low-side MOSFETs to recirculate the motor current and avoid further increasing the supply voltage through diode rectification.
The default selection for high-side or low-side ASC is configurable through the ASC_POLARITY bit. However, in order to provide robustness through a variety of operating conditions and system fault scenarios, the DRV8363-Q1 will automatically switch between high-side and low-side ASC. This behavior is summarized in the chart below: