The TPS38800-Q1/TPS388R0-Q1 takes
several actions on the ACT 0→1 transition:
- After ACT 0→1 transition:
- All TPS38800-Q1/TPS388R0-Q1 inputs selected with auto-mask register
AMSK_ON start with masked (disabled) interrupts for Under-Voltage
High Frequency (UVHF) conditions.
- As each rail passes
the MON's OFF threshold, automatically (and expected to happen
within about 5-10 μs) the relevant UV and OV interrupts are unmasked
and enabled/disabled according to the IEN_UVHF and IEN_OVHF
registers.
- After SEQ_TOUT timeout:
- TPS38800-Q1/TPS388R0-Q1 is in ACTIVE state and starts normal
monitoring.