ISO1044

활성

소형 패키지의 절연 CAN FD 트랜시버

제품 상세 정보

Rating Catalog Isolation rating Basic Data rate (max) (Mbps) 5 Working isolation voltage (VIOWM) (Vrms) 459 Surge isolation voltage (VIOSM) (VPK) 5000, 8000 Transient isolation voltage (VIOTM) (VPK) 4242 Withstand isolation voltage (VISO) (Vrms) 3000 CMTI (min) (kV/µs) 85 Supply voltage (V) 1.71 to 5.5, 4.5 to 5.5 Bus fault voltage (V) -58 to 58 Common-mode voltage (V) -12 to 12 Operating temperature range (°C) -40 to 125
Rating Catalog Isolation rating Basic Data rate (max) (Mbps) 5 Working isolation voltage (VIOWM) (Vrms) 459 Surge isolation voltage (VIOSM) (VPK) 5000, 8000 Transient isolation voltage (VIOTM) (VPK) 4242 Withstand isolation voltage (VISO) (Vrms) 3000 CMTI (min) (kV/µs) 85 Supply voltage (V) 1.71 to 5.5, 4.5 to 5.5 Bus fault voltage (V) -58 to 58 Common-mode voltage (V) -12 to 12 Operating temperature range (°C) -40 to 125
SOIC (D) 8 29.4 mm² 4.9 x 6
  • Meets the ISO 11898-2:2016 physical layer standard
  • Supports classic CAN up to 1 Mbps and FD (flexible data rate) up to 5 Mbps
  • Protection features
    • DC Bus Fault Protection Voltage: ±58 V
    • IEC ESD tolerance on bus pins: ±8 kV
    • HBM ESD tolerance on bus pins: ±10 kV
    • Driver dominant time out (TXD DTO)
    • Undervoltage protection on VCC1 and VCC2
  • Common-mode voltage range: ±12 V
  • Ideal passive, high impedance bus terminals when unpowered
  • High CMTI: 85 kV/µs minimum
  • VCC1 voltage range: 1.71 V to 5.5 V
    • Supports 1.8-V, 2.5-V, 3.3-V and 5.0-V logic interface to the CAN controller
  • VCC2 voltage range: 4.5 V to 5.5 V
  • Robust electromagnetic compatibility (EMC)
    • System-Level ESD, EFT, and surge Immunity
    • Low Emissions
  • Ambient temperature range: –40°C to +125°C
  • 8-SOIC package
  • Safety-related certifications:
    • All certifications planned
    • VDE reinforced insulation per DIN VDE V 0884-11:2017-01
    • UL 1577 component recognition program
    • IEC 60950-1, IEC 62368-1, IEC 61010-1 and GB 4943.1-2011 certifications
  • Meets the ISO 11898-2:2016 physical layer standard
  • Supports classic CAN up to 1 Mbps and FD (flexible data rate) up to 5 Mbps
  • Protection features
    • DC Bus Fault Protection Voltage: ±58 V
    • IEC ESD tolerance on bus pins: ±8 kV
    • HBM ESD tolerance on bus pins: ±10 kV
    • Driver dominant time out (TXD DTO)
    • Undervoltage protection on VCC1 and VCC2
  • Common-mode voltage range: ±12 V
  • Ideal passive, high impedance bus terminals when unpowered
  • High CMTI: 85 kV/µs minimum
  • VCC1 voltage range: 1.71 V to 5.5 V
    • Supports 1.8-V, 2.5-V, 3.3-V and 5.0-V logic interface to the CAN controller
  • VCC2 voltage range: 4.5 V to 5.5 V
  • Robust electromagnetic compatibility (EMC)
    • System-Level ESD, EFT, and surge Immunity
    • Low Emissions
  • Ambient temperature range: –40°C to +125°C
  • 8-SOIC package
  • Safety-related certifications:
    • All certifications planned
    • VDE reinforced insulation per DIN VDE V 0884-11:2017-01
    • UL 1577 component recognition program
    • IEC 60950-1, IEC 62368-1, IEC 61010-1 and GB 4943.1-2011 certifications

The ISO1044B device is a galvanically-isolated controller area network (CAN) transceiver that meets the specifications of the ISO11898-2 (2016) standard. The ISO1044B device offers ±58-V DC bus fault protection and ±12-V common-mode voltage range. The device supports up to 5-Mbps data rate in CAN FD mode allowing much faster transfer of payload compared to classic CAN. This device uses a silicon dioxide (SiO2) insulation barrier with a withstand voltage of 3000 VRMS and a working voltage of 450 VRMS. Electromagnetic compatibility has been significantly enhanced to enable system-level ESD, EFT, surge, and emissions compliance. Used in conjunction with isolated power supplies, the device protects against high voltage, and prevents noise currents from the bus from entering the local ground. The ISO1044B device supports a wide ambient temperature range of –40°C to +125°C. The device is available in the small SOIC-8 (D) package which significantly reduces the solution size compared to a traditional approach using optocouplers to isolate the CAN transceiver.

The ISO1044B device is a galvanically-isolated controller area network (CAN) transceiver that meets the specifications of the ISO11898-2 (2016) standard. The ISO1044B device offers ±58-V DC bus fault protection and ±12-V common-mode voltage range. The device supports up to 5-Mbps data rate in CAN FD mode allowing much faster transfer of payload compared to classic CAN. This device uses a silicon dioxide (SiO2) insulation barrier with a withstand voltage of 3000 VRMS and a working voltage of 450 VRMS. Electromagnetic compatibility has been significantly enhanced to enable system-level ESD, EFT, surge, and emissions compliance. Used in conjunction with isolated power supplies, the device protects against high voltage, and prevents noise currents from the bus from entering the local ground. The ISO1044B device supports a wide ambient temperature range of –40°C to +125°C. The device is available in the small SOIC-8 (D) package which significantly reduces the solution size compared to a traditional approach using optocouplers to isolate the CAN transceiver.

다운로드 스크립트와 함께 비디오 보기 동영상

관심 가지실만한 유사 제품

open-in-new 대안 비교
비교 대상 장치와 동일한 기능을 지원하는 핀 대 핀
ISO1042 활성 70V 버스 고장 방지 및 유연한 데이터 전송률을 지원하는 절연 CAN 트랜시버 Higher isolation voltage isolated CAN transceiver with 70-V bus fault protection & flexible data rate

기술 자료

star =TI에서 선정한 이 제품의 인기 문서
검색된 결과가 없습니다. 검색어를 지우고 다시 시도하십시오.
16개 모두 보기
유형 직함 날짜
* Data sheet ISO1044 Isolated CAN FD Transceiver in Small Package datasheet (Rev. A) 2020/07/15
Application note Top Design Questions About Isolated CAN Bus Design (Rev. B) PDF | HTML 2024/10/24
Certificate VDE Certificate for Reinforced Isolation for DIN EN IEC 60747-17 (Rev. S) 2024/02/29
Certificate CSA Certificate for ISO1044BD 2023/03/16
Certificate CQC Certificate for ISOxxD (Rev. A) 2023/02/07
Product overview Isolating a CAN Bus (Rev. A) PDF | HTML 2023/01/13
Certificate TUV Certificate for Isolation Devices (Rev. K) 2022/08/05
Certificate UL Certificate of Compliance File E181974 Vol 4 Sec 6 (Rev. P) 2022/08/05
Application brief Isolate Your CAN Systems Without Compromising on Performance or Space (Rev. F) PDF | HTML 2022/08/04
Application brief How to Design an Isolated CAN Port for Space-Constrained Industrial Applications (Rev. A) PDF | HTML 2022/07/06
White paper Why are Digital Isolators Certified to Meet Electrical Equipment Standards? 2021/11/16
White paper Distance Through Insulation: How Digital Isolators Meet Certification Requiremen PDF | HTML 2021/06/11
Application brief How to Isolate Signal and Power in Isolated CAN Systems (Rev. C) PDF | HTML 2021/05/25
Application note Isolated CAN Reference Design (Rev. E) 2020/07/22
User guide ISO1044DEVM Isolated CAN Evaluation Module PDF | HTML 2020/03/20
Technical article The hidden cost of optocouplers for isolated RS-485 and CAN designs PDF | HTML 2019/01/28

설계 및 개발

추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.

평가 보드

ISO1044DEVM — ISO1044 절연 CAN 트랜시버 평가 모듈

ISO1044DEVM is an evaluation module used to evaluate the small package, basic isolation, high speed, robust EMC isolated CAN transceiver in the SOIC-8D package. The EVM features enough test points and jumper options to evaluate the device with minimal external components.
사용 설명서: PDF | HTML
TI.com에서 구매 불가
시뮬레이션 모델

ISO1044BD IBIS Model

SLLM450.ZIP (81 KB) - IBIS Model
패키지 CAD 기호, 풋프린트 및 3D 모델
SOIC (D) 8 Ultra Librarian

주문 및 품질

포함된 정보:
  • RoHS
  • REACH
  • 디바이스 마킹
  • 납 마감/볼 재질
  • MSL 등급/피크 리플로우
  • MTBF/FIT 예측
  • 물질 성분
  • 인증 요약
  • 지속적인 신뢰성 모니터링
포함된 정보:
  • 팹 위치
  • 조립 위치

권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.

지원 및 교육

TI 엔지니어의 기술 지원을 받을 수 있는 TI E2E™ 포럼

콘텐츠는 TI 및 커뮤니티 기고자에 의해 "있는 그대로" 제공되며 TI의 사양으로 간주되지 않습니다. 사용 약관을 참조하십시오.

품질, 패키징, TI에서 주문하는 데 대한 질문이 있다면 TI 지원을 방문하세요. ​​​​​​​​​​​​​​

동영상