SPRSP93B November 2024 – September 2025 F29H850TU , F29H859TU-Q1
ADVMIX
Refer to the PDF data sheet for device specific package drawings
The following address map tables apply to all part numbers.
| FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS | FLASH BANKS |
|---|---|---|---|---|---|
| FRI-1 (CPU1 program) | RP0 | 4KB | 0x10D80000 | 0x10D80FFF | FLC1.B0/B1 |
| RP1 | 4KB | 0x10D84000 | 0x10D84FFF | FLC1.B2/B3 | |
| RP2 | 4KB | 0x10D88000 | 0x10D88FFF | FLC2.B0/B1 | |
| RP3 | 4KB | 0x10D8C000 | 0x10D8CFFF | FLC2.B2/B3 | |
| FRI-2 (CPU3 program)(1) | RP0 | 4KB | 0x10D90000 | 0x10D90FFF | N/A |
| RP1 | 4KB | 0x10D94000 | 0x10D94FFF | N/A | |
| FRI-3 (Update region) | RP0 | 4KB | 0x10D98000 | 0x10D98FFF | N/A |
| RP1 | 4KB | 0x10D9C000 | 0x10D9CFFF | N/A |
| FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS |
FLASH BANKS (SWAP = 0) | FLASH BANKS (SWAP = 1) |
|---|---|---|---|---|---|---|
| FRI-1 (CPU1 program) | RP0 | 4KB | 0x10D80000 | 0x10D80FFF | FLC1.B0/B1 | FLC1.B2/B3 |
| RP1 | 4KB | 0x10D84000 | 0x10D84FFF | FLC2.B0/B1 | FLC2.B2/B3 | |
| RP2 | 4KB | 0x10D88000 | 0x10D88FFF | N/A | N/A | |
| RP3 | 4KB | 0x10D8C000 | 0x10D8CFFF | N/A | N/A | |
| FRI-2 (CPU3 program)(1) | RP0 | 4KB | 0x10D90000 | 0x10D90FFF | N/A | N/A |
| RP1 | 4KB | 0x10D94000 | 0x10D94FFF | N/A | N/A | |
| FRI-3 (Update region) | RP0 | 4KB | 0x10D98000 | 0x10D98FFF | FLC1.B2/B3 | FLC1.B0/B1 |
| RP1 | 4KB | 0x10D9C000 | 0x10D9CFFF | FLC2.B2/B3 | FLC2.B0/B1 |
| FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS | FLASH BANKS |
|---|---|---|---|---|---|
| FRI-1 (CPU1 program) | RP0 | 4KB | 0x10D80000 | 0x10D80FFF | FLC1.B0/B1 |
| RP1 | 4KB | 0x10D84000 | 0x10D84FFF | FLC1.B2/B3 | |
| RP2 | 4KB | 0x10D88000 | 0x10D88FFF | N/A | |
| RP3 | 4KB | 0x10D8C000 | 0x10D8CFFF | N/A | |
| FRI-2 (CPU3 program)(1) | RP0 | 4KB | 0x10D90000 | 0x10D90FFF | FLC2.B0/B1 |
| RP1 | 4KB | 0x10D94000 | 0x10D94FFF | FLC2.B2/B3 | |
| FRI-3 (Update region) | RP0 | 4KB | 0x10D98000 | 0x10D98FFF | N/A |
| RP1 | 4KB | 0x10D9C000 | 0x10D9CFFF | N/A |
| FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS |
FLASH BANKS (SWAP = 0) | FLASH BANKS (SWAP = 1) |
|---|---|---|---|---|---|---|
| FRI-1 (CPU1 program) | RP0 | 4KB | 0x10D80000 | 0x10D80FFF | FLC1.B0/B1 | FLC1.B2/B3 |
| RP1 | 4KB | 0x10D84000 | 0x10D84FFF | N/A | N/A | |
| RP2 | 4KB | 0x10D88000 | 0x10D88FFF | N/A | N/A | |
| RP3 | 4KB | 0x10D8C000 | 0x10D8CFFF | N/A | N/A | |
| FRI-2 (CPU3 program)(1) | RP0 | 4KB | 0x10D90000 | 0x10D90FFF | FLC2.B0/B1 | FLC2.B2/B3 |
| RP1 | 4KB | 0x10D94000 | 0x10D94FFF | N/A | N/A | |
| FRI-3 (Update region) | RP0 | 4KB | 0x10D98000 | 0x10D98FFF | FLC1.B2/B3 | FLC1.B0/B1 |
| RP1 | 4KB | 0x10D9C000 | 0x10D9CFFF | FLC2.B2/B3 | FLC2.B0/B1 |