SBASAE4 December 2025 ADS125P08
PRODUCTION DATA
Setting the SEQ_MODE[1:0] bits in the SEQUENCER_CFG register to 00b selects the single-shot mode (no sequencing). In this mode, the device only executes one sequence step, one time. The SEQ_STEP_x_EN bits are ignored in single-shot mode. The STEP_INIT[4:0] bits in the CONVERSION_CTRL register point to the sequence step x (x = 0 to 31) to be executed:
Figure 7-21 shows a flow chart of the sequencer operation, including the behavior in single-shot mode (SEQ_MODE[1:0] = 00b).
The device configures the ADC based on the step configuration page x, adds the programmable delay time defined by the STEPx_DELAY[15:0] bits and then starts ADC conversions. The number of ADC conversions (up to 512) is set by the STEPx_NUM_CONV[3:0] bits in the STEPx_ADC_REF_CFG register.
After completion of the ADC conversions (1 up to 512) in single-shot mode, the device enters standby mode (STBY_MODE = 1b) or remains fully powered in idle mode (STBY_MODE = 0b).