SBASAE4 December 2025 ADS125P08
PRODUCTION DATA
Two FIFO threshold levels, FIFO_THRES_A[8:0] and FIFO_THRES_B[8:0], are available to monitor FIFO operation. The DRDY pin can be programmed to detect whenever the depth of the FIFO (indicated by the FIFO_DEPTH[8:0] bits) reaches any of the two thresholds. Set the DRDY_CFG[1:0] bits to 11b to enter this mode.
Note that when writing new values to either FIFO_THRES_A[8:0] and FIFO_THRES_B[8:0], the FIFO does not reset or flush. It is recommended that the user stops the sequencer, disables the FIFO, changes the thresholds, enables the FIFO and then starts the sequencer again.
See the Auto-Sequencer and DRDY Behavior section for details on the FIFO thresholds and the DRDY_CFG [1:0] = 11b mode.