SLAAET6 August 2025
The ground clearance around the through-hole connector signal via, also referred to as via anti-pad, can significantly impact the trace impedance due to the influence on the parasitic capacitance and return current path of the via. A larger anti-pad reduces parasitic capacitance between the signal via and the ground plane, resulting in an increase of impedance, while a smaller anti-pad lowers impedance. Proper anti-pad size is critical for minimizing impedance discontinuity.