SLAAET6 August   2025

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1S-Parameter Definition
    1. 1.1 Insertion Loss (S21)
    2. 1.2 Return Loss (S11)
  5. 2High-Speed Signal Design Example Of FPD-Link™ Serializer Body
    1. 2.1 Design Example Overview
    2. 2.2 Key Points in High-Speed FPD-Link Layout Design
  6. 3Factors Impacting Return Loss and Optimization Guidelines
    1. 3.1 Transmission Line Impedance Impact
    2. 3.2 AC Coupling Capacitor Landing Pad Impact And Optimization
      1. 3.2.1 Mitigation Strategy: Anti-Pad Implementation
      2. 3.2.2 Simulation Results With Ansys® HFSS
    3. 3.3 Through-Hole Connector Footprint Impact and Optimization
      1. 3.3.1 Through-Hole Connector Via Anti-Pad Impact
        1. 3.3.1.1 Simulation Results With Ansys® HFSS
      2. 3.3.2 Surrounding Ground Vias Impact
        1. 3.3.2.1 Simulation Results (Surrounding Ground Vias Impact)
      3. 3.3.3 Non-Functional Pad Impact
        1. 3.3.3.1 Simulation Results (Non-Functional Pad Impact)
    4. 3.4 Generic Signal Via Impact and Optimization
      1. 3.4.1 Simulation Results
    5. 3.5 ESD Diode Parasitic Capacitance Impact and Optimization
  7. 4Summary

Generic Signal Via Impact and Optimization

The generic signal via is similar to the connector signal via analyzed in Section 3.3. Both vias require optimization of anti-pad size and ground via spacing to manage parasitic capacitance and inductance to maintain impedance continuity. Figure 3-13 depicts the simulation model for a generic signal via, including adjacent ground plane with variable anti-pad clearances and symmetric ground vias arranged in a four-via quadrant configuration.