SLLSFT1 October 2026 TIOM2212
ADVANCE INFORMATION
The TIOM2212 signals a fault when the C/Q driver exceeds the CQ_ILIM for longer than the blanking time duration. The current limit, blanking time, and auto-retry time can each be set in the CQ_DRV_CFG register. Upon a C/Q overcurrent fault, the CQ_OC bit is set in CPIREQ register. This condition can be ignored by masking the bit using the CPIMASK register. The device supports two modes (set by CQ_DRV_AR_DIS) when the C/Q driver exceeds CQ_ILIM. The device can either continue to supply current indefinitely until it reaches the thermal shutdown threshold, or it can operate in auto-retry mode. In auto-retry mode, the device supplies current equal to CQ_ILIM for a duration equal to the current blanking time, and then disables the output for a duration equal to the auto-retry time. As long as the C/Q driver continues to exceed CQ_ILIM, this routine will repeat a number of times until it reaches the value set in the CQ_DRV_MAX_AR field (and it will repeat an infinite number of times if the value of this field is 0000b).