FAULT state is a device-internally generated mode that cannot be manually set by the user.
If one or more channels of the device are in PLAY state and encounter a fault, the device needs to take protective actions and shutdown one or more audio channels. The output FETs of only the affected channels are turned off and the output pins become high impedance. The reported state for affected channels is 'FAULT'.
Possible reasons for individual channels to enter this state are:
Possible reason for all channels to enter this state is: