SLUSG21A May 2025 – September 2025 UCC25661
PRODUCTION DATA
The voltage programmed for VTSETB voltage configures the minimum operating frequency for IPPC operation and the maximum dead time. The difference between VTSETA and VTSETB configures the integrator time constants that set the FBReplica magnitude for a given power output, enabling setting the overload power (OLP) and over-current protection (OCP) thresholds independently. In the table value TSET voltage values indicated are nominal values. Maximum and minimum range used for each TSET setting is within ± 48mV from nominal value.
| TSET OPTION NUMBER | TSET VOLTAGE (V) FOR 3.5V OCP | MINIMUM FREQUENCY FOR IPPC OPERATION (kHz) | INTEGRATOR TIME CONSTANT (ns) | MAXIMUM DEAD-TIME (μs) |
|---|---|---|---|---|
| 17 | 2.295 | 698.6 | 68 | 0.5 |
| 16 | 2.168 | 591.6 | 80 | 0.5 |
| 15 | 2.041 | 501 | 93 | 0.5 |
| 14 | 1.914 | 424.3 | 112 | 0.5 |
| 13 | 1.787 | 359.3 | 132 | 1 |
| 12 | 1.66 | 304.3 | 156 | 1 |
| 11 | 1.533 | 256.7 | 184 | 1 |
| 10 | 1.416 | 218.2 | 214 | 1 |
| 9 | 1.299 | 184.8 | 257 | 1 |
| 8 | 1.182 | 156.5 | 304 | 1 |
| 7 | 1.074 | 132.5 | 359 | 1 |
| 6 | 0.967 | 112.2 | 424 | 1 |
| 5 | 0.850 | 95 | 490 | 1 |
| 4 | 0.742 | 80.5 | 588 | 1 |
| 3 | 0.644 | 68.1 | 694 | 1 |
| 2 | 0.547 | 57.7 | 820 | 1 |
| 1 | 0.450 | 48.9 | 968 | 1 |
| X(1) | < 0.392 | — | X | — |