The Reference DAC can drive an external load connected to the COMPA_IN analog node when the peripheral clock frequency is 2 MHz or 24 MHz. This is valid for:
- Active and Low-Power AUX operational mode
- Active and Idle mode (defined by TI's Power Manager)
The user must enable the buffer when the Reference DAC interfaces an external load.
Load support:
- Resistive loads > 10 MΩ
- From the AUX_DAC_Drvier specification: “If the DAC is operating at 2.0 V, the load is required to have a resistance >>10 MΩ or be purely capacitive . If this condition is not met, the CHP must be used to reduce the VOUT error.”
- Capacitive loads < 200 pF (always stable)
- Capacitive loads
- R+C