TIDUF85A August 2024 – December 2024
Table 3-1 describes the TIDA-010955 connection point and Table 3-2 lists the maximum input rating.
| DESIGNATOR | DESCRIPTION |
|---|---|
T1, T2, T3, T4 | Current transformers for channels 1, 2, 3, and 4. Feed through PV cabling. |
J1, J2, J3, J4 | External current sensor input for channels 1, 2, 3, and 4 |
J7 | Connector for auxiliary power (8V to 16V) |
J5_1, J5_2 | HSEC Connector for C2000 control card |
J6 | Debug header (Contains GPIOs, Voltage rails and a SPI) |
J8A, J8B | Positive and negative input of string voltage for arc labeling circuit |
J9A, J9B | Positive and negative input of arc gap voltage for labeling circuit |
TP9, TP11, TP17, TP20 | Positive output of CT of channels 1, 2, 3, and 4 |
TP10, TP12, TP19, TP21 | Negative output of CT of channels 1, 2, 3, and 4 |
TP2, TP4, TP6, TP7 | Input of band-pass filter after gain stage for channels 1, 2, 3, and 4 |
TP35, TP36, TP37, TP38 | Output of low pass stage of bandpass filter for channels, 1, 2, 3, and 4 |
TP1, TP3, TP4, TP8 | Output of band-pass filter for channels 1, 2, 3, and 4. |
TP16 | 5V rail |
TP18 | 3.3V rail |
TP22 | Output of window comparator for arc labeling |
TP23, TP26 | Positive and negative output of U11 for string voltage sensing (differential output) |
TP24 | Single-ended output of string voltage sensing |
| TP30, TP2 | Positive and negative output of U17 for arc gap voltage sensing (differential output) |
TP31 | Single-ended output of arc gap voltage sensing |
TP13, TP14, TP15, TP39, TP40, TP25, TP29, TP33 | GND |
| CONNECTOR | MAXIMUM VOLTAGE (V) | MAXIMUM CURRENT (A) |
|---|---|---|
J9A, J9B | 1500 | Limited by resistor divider |
J8A, J8B | 1500 | Limited by resistor divider |
J7 | 16 | 0.6A (limited by eFuse) |
J1, J2, J3, J4 | 3.3 | Limited by burden resistor (R5, R10, R15, or R20) |