DLPS037H October 2014 – June 2024 DLPC900
PRODUCTION DATA
| MIN | MAX | UNIT | |||
|---|---|---|---|---|---|
| ƒclock | Clock frequency, TCK | 10 | MHz | ||
| tc | Cycle time, TCK | 100 | ns | ||
| tw(H) | Pulse duration, high | 50% to 50% reference points (signal) | 40 | ns | |
| tw(L) | Pulse duration, low | 50% to 50% reference points (signal) | 40 | ns | |
| tt | Transition time, tt = tf / tr | 20% to 80% reference points (signal) | 5 | ns | |
| tsu | Setup time, TDI valid before TCK↑ | 8 | ns | ||
| th | Hold time, TDI valid after TCK↑ | 2 | ns | ||
| tsu | Setup time, TMS1 valid before TCK↑ | 8 | ns | ||
| th | Hold time, TMS1 valid after TCK↑ | 2 | ns | ||